A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Programmable flow heart cutting solid phase extraction using polydopamine coated microfibrous sorbent as a front-end to UHPLC for direct determination of xenobiotic residues in surface water. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Automation and hyphenation of multiple steps were used for the sensitive determination of xenobiotic residues in surface waters. The online hyphenated sequential injection analysis instrumentation used surface-modified microfibrous sorbent for the effective solid phase extraction of 1.0 mL of sample into 100 μL zone, then subjected to the reversed-phase ultra-high performance liquid chromatography (SIA-SPE-UHPLC). The SPE column was packed with polypropylene microfibers and coated with polydopamine by rinsing with the dopamine solution. The freshly prepared column was used for highly reproducible extraction of more than 200 samples in the SIA-SPE-UHPLC method. The matrix calibration covered the expected range with limits of detection in the range 0.1-0.9 μg/L. The method precision was <13 % RSD (at 3 concentration levels), and the method accuracy was in the range 86.5-114.8 %. The sample throughput of the method was 5 samples/hour when the separation took 12 min, including a 5 min SPE step of the next sample run in parallel. The performance of the developed method was demonstrated with the analysis of fifteen river water samples spiked with eleven residues of xenobiotics (ivermectin, fenbendazole, praziquantel, ibuprofen, diclofenac, 17α-ethynylestradiol, androstenedione, carbamazepine, omeprazole, sotalol, and caffeine) at the levels typical for such monitoring. Initial sample treatment prior to the automated analysis consisted only of methanol addition, pH adjustment, and centrifugation. The innovations in the manifold and process that contribute to the modern and effective analysis of environmental samples are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2025.128571DOI Listing

Publication Analysis

Top Keywords

solid phase
8
phase extraction
8
microfibrous sorbent
8
determination xenobiotic
8
xenobiotic residues
8
residues surface
8
programmable flow
4
flow heart
4
heart cutting
4
cutting solid
4

Similar Publications