A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Durable, Breathable, and Flexible Sensor Based on Vapor-Phase Polymerized PANI-Coated PUC-CoNi-LDH@PANI Composite for Continuous Sweat Glucose Monitoring. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The increasing prevalence of diabetes, associated with complications such as heart attacks, strokes, and kidney failure, has necessitated the development of diverse, customized wearable sensors, particularly for the elderly. In this study, a fully integrated flexible sensor based on a PUC-CoNi-LDH@PANI nanocomposite is fabricated. This involves the direct growth of CoNi-double layer hydroxide (CoNi-LDH) through a facile template-free solvothermal treatment, followed by the vapor phase polymerization (VPP) of π-conjugated polyaniline (PANI) on a flexible electrospun polyurethane/chitosan (PUC) mat. Electrochemical studies indicate that the PUC-CoNi-LDH@PANI sensor exhibits ultrahigh sensitivity (2 187.62, 1 752.06 µA mm cm) across an acceptable linear range (0.001 to 3.70 mm) and has an extremely low detection limit (0.13 µm). The superior sensing performance is attributed to the synergistic effects of enhanced catalytic activity, dramatically enlarged surface area of CoNi-LDH nano-flake arrays, mass transfer capability, and improved conductivity due to PANI modification. Moreover, this novel, flexible, nanofiber-based sensor demonstrates excellent reliability for practical glucose detection in human sweat, thereby affirming its potential as a candidate for flexible microelectronics and as a top choice for flexible and wearable healthcare diagnostics systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adhm.202501754DOI Listing

Publication Analysis

Top Keywords

flexible sensor
8
sensor based
8
flexible
6
durable breathable
4
breathable flexible
4
sensor
4
based vapor-phase
4
vapor-phase polymerized
4
polymerized pani-coated
4
pani-coated puc-coni-ldh@pani
4

Similar Publications