Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

: Additive manufacturing (AM) enables the production of cementless acetabular cups with porous surfaces that facilitate early osseointegration. Directed energy deposition (DED), a form of AM, allows the direct welding of porous structures onto metal substrates without requiring a vacuum environment, offering advantages over conventional powder bed fusion methods. Despite growing interest in DED, no prospective clinical studies evaluating DED-based acetabular components have been published to date. This study assessed short-term outcomes of a DED-based 3D-printed acetabular cup in total hip arthroplasty (THA). : A total of 120 patients who underwent primary cementless THA using the Corentec Mirabo Z acetabular cup were prospectively enrolled. Among them, 124 hips from 100 patients who had completed a minimum of 24 months of follow-up were included in the analysis. Clinical outcomes were assessed using the Harris hip score (HHS), WOMAC, EQ-5D-5L, and pain NRS. Radiographic evaluation included measurements of cup position, osseointegration, and detection of interfacial or polar gaps on CT and plain radiographs. Implant-related complications were also recorded. : At a mean follow-up of 34.6 months, the implant survival rate was 99.3%, with one revision due to suspected osseointegration failure. The HHS improved from 56.6 to 91.4 at 24 months, and the NRS decreased from 6.2 to 1.1 (both < 0.001). Interfacial gaps were observed in 58.1% of cases on CT, though most were <1 mm and not clinically significant. Common postoperative issues included greater trochanteric pain syndrome, squeaking, and iliotibial band tightness, all of which were resolved with conservative treatment. : DED-based 3D-printed acetabular cups demonstrated favorable short-term clinical and radiographic outcomes, with high survivorship and reliable early osseointegration in cementless THA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12249783PMC
http://dx.doi.org/10.3390/jcm14134527DOI Listing

Publication Analysis

Top Keywords

acetabular cup
12
short-term outcomes
8
total hip
8
hip arthroplasty
8
3d-printed acetabular
8
directed energy
8
energy deposition
8
acetabular
5
outcomes cementless
4
cementless total
4

Similar Publications

Background And Objective: With obese individuals experiencing osteoarthritis (OA) at early stages of life, hip resurfacing (HR) has emerged as an alternative to arthroplasty. The purpose is to conduct a short-term analysis on patients with obesity who underwent primary HR for OA compared to a benchmark control group of non-obese patients.

Materials And Methods: Patients with a body mass index (BMI) ≥ 30 kg/m2 who underwent HR from 2010 to 2021 were eligible for inclusion.

View Article and Find Full Text PDF

The impact of surgeons' visual angle misperception on acetabular cup positioning accuracy: a retrospective multicentre cohort study.

Int J Surg

September 2025

Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.

Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons' visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA.

View Article and Find Full Text PDF

Introduction: anatomical deformities such as developmental dysplasia of the hip (DDH) and Perthes disease represent a challenge for reconstruction. The use of 3D-printed models can be helpful for assessing the deformity, bone mass, implant size, and orientation.

Objectives: to prospectively evaluate the outcomes of 3D simulation in primary total hip arthroplasty.

View Article and Find Full Text PDF

Background: Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.

View Article and Find Full Text PDF

Background: Acetabular reconstruction is often challenging in revision hip arthroplasty, especially in the face of moderate to severe acetabular bone deficiency. In some severe bone defects, double-metal tantalum cups can improve the contact area between bone and implants, increase the surface area for bone ingrowth, and better restore the anatomical position of the acetabulum. Furthermore, with a good press-fit, the auxiliary screw has a minimal effect on acetabular cup stability.

View Article and Find Full Text PDF