A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimal Arterial Pressure Transducer Positioning for Neurocritical Care Patients: A Review. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This narrative review addresses the critical issue of arterial transducer positioning for cerebral perfusion pressure (CPP) measurement in neurocritical care. Despite CPP's importance in guiding management, optimal transducer placement remains ambiguous and unaddressed by current guidelines. We synthesized evidence from 20 relevant articles to inform standardization efforts. Key findings include a 10-12 mmHg CPP discrepancy between phlebostatic axis and Monro foramen transducer locations at 30° head elevation. There is no consensus on anatomical landmarks for "head-level" measurement, and only one guideline explicitly advises against the phlebostatic axis approach. Limited clinical evidence suggests increased institutionalization rates for patients with measurement discrepancies. Emerging dual-transducer strategies aim to address these challenges. The review highlights significant variability in CPP measurement practices, potentially impacting patient care and research interpretation. We emphasize the urgent need for standardized protocols and improved reporting in research. Addressing this variability is crucial for optimizing neurocritical care management and enhancing research comparability. Our findings underscore the importance of consistent arterial transducer positioning in neurocritical care and call for further research to establish evidence-based standardization, ultimately improving patient outcomes and research quality in this critical field.

Download full-text PDF

Source
http://dx.doi.org/10.1089/neu.2024.0463DOI Listing

Publication Analysis

Top Keywords

neurocritical care
16
transducer positioning
12
positioning neurocritical
8
arterial transducer
8
cpp measurement
8
phlebostatic axis
8
transducer
5
care
5
optimal arterial
4
arterial pressure
4

Similar Publications