98%
921
2 minutes
20
Background: Stroke and its related complications, place significant burdens on human society in the twenty-first century, and lead to substantial demands for upper limb rehabilitation. To fulfill the rehabilitation needs, human-machine interaction (HMI) technology strives continuously. Depends on the involvement of subject, HMI strategy can be classified as passive or active. Compare to passive modalities, active strategies are believed to be more effective in promoting neuroplasticity and motor recovery for post-stroke survivors in sub-acute and chronic phase. However, post-stroke survivors usually experience weak upper arms, limited range of motion (ROM) and involuntary excessive movement patterns. Distinguishing between complex subtle motion intentions and excessive involuntary movements in real-time remains a challenge in current research, which impedes the application of active HMI strategies in clinical practice.
Method: An Up-limb Rehabilitation Device and Utility System (UarDus) is proposed along with 3 HMI strategies namely robot-in-charge, therapist-in-charge and patient-in-charge. Based on physiological structure of human upper-limb and scapulohumeral rhythm (SHR) of shoulder, a base exoskeleton with 14 degrees of freedoms (DoFs) is designed as foundation of the 3 strategies. Passive robot-in-charge and therapist-in-charge strategies provides fully-assisted rehabilitation options. The active patient-in-charge strategy incorporates data acquisition matrices and a new deep learning model, which is developed based on Convolutional Neural Network (CNN) and Transformer structure, aims to capture subtle motion intentions. Motors' current is monitored and the surge in the current is identified adopting Discrete Wavelet Transform (DWT) method for safety concerns.
Results: Kinematically, the work space of the base exoskeleton is presented first. Utilizing motion capture technology, the glenohumeral joint (GH) centers of both human and exoskeleton exhibit well-matched motion curves, suggesting a comfortable dynamic wear experience. For robot-in-charge and therapist-in-charge strategy, the desired and measured angle-time curve present good correlation, with low phase difference, which serve the purpose of real-time control. Featuring the patient-in-charge strategy, Kernel Density Estimation (KDE) result suggesting reasonable sensor-machine-human synergy. Applying K-fold (K = 10) cross-validation method, the classification accuracy of the proposed model with outstanding response time achieves an average of 99.7% for the designated 15 actions, signifies its capability for subtle motion intention recognition in real-time. Additionally, signal surge is easily identified with DWT.
Conclusions: An upper-limb exoskeleton hardware device named UarDus is constructed, along with three HMI modalities, offering both passive and active rehabilitation approaches. The proposed system is validated through a proof-of-concept study on a subject who underwent a craniotomy for a hemorrhagic stroke, demonstrating the possibility for post-stroke individuals to engage in safe, personalized rehabilitation training in real-time, with a dynamically comfortable wear experience.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12232190 | PMC |
http://dx.doi.org/10.1186/s12984-025-01680-2 | DOI Listing |
Nanomicro Lett
September 2025
Nanomaterials & System Lab, Major of Mechatronics Engineering, Faculty of Applied Energy System, Jeju National University, Jeju, 63243, Republic of Korea.
Wearable sensors integrated with deep learning techniques have the potential to revolutionize seamless human-machine interfaces for real-time health monitoring, clinical diagnosis, and robotic applications. Nevertheless, it remains a critical challenge to simultaneously achieve desirable mechanical and electrical performance along with biocompatibility, adhesion, self-healing, and environmental robustness with excellent sensing metrics. Herein, we report a multifunctional, anti-freezing, self-adhesive, and self-healable organogel pressure sensor composed of cobalt nanoparticle encapsulated nitrogen-doped carbon nanotubes (CoN CNT) embedded in a polyvinyl alcohol-gelatin (PVA/GLE) matrix.
View Article and Find Full Text PDFMagn Reson Chem
September 2025
Institute of Scientific and Industrial Research, Osaka University, Osaka, Japan.
We reveal contrasting behaviors in molecular motion between the two materials, including the identification of resonance-enhanced dynamic features in elastomers. We present a depth-resolved analysis of molecular dynamics in semicrystalline polytetrafluoroethylene (PTFE) and fully amorphous fluorinated elastomer (SIFEL) films using static-gradient solid-state F NMR imaging. By measuring spin-lattice relaxation rates ( ) at multiple frequencies and evaluating the corresponding spectral density functions, we reveal distinct dynamic behaviors between the two materials.
View Article and Find Full Text PDFJ Surg Case Rep
September 2025
Department of Orthopaedics and Sports Medicine, University at Buffalo, 462 Grider Street, Buffalo, NY 14215, United States.
An 8-year-old girl fell onto her outstretched arm, sustaining proximal ulna and radial neck fractures. After closed reduction and casting in the emergency department, radiographs showed improved alignment but limited bony detail. A CT scan performed 3 days later demonstrated 18° apex-medial angulation of the radial neck, slight radiocapitellar subluxation, and subtle calcification near the trochlear notch, concerning intra-articular injury.
View Article and Find Full Text PDFInt J Biol Macromol
September 2025
College of Pharmacy, Guangxi University of Chinese Medicine, Nanning 530200, China. Electronic address:
Conductive hydrogels have emerged as promising materials for flexible wearable electronics; however, their facile fabrication remains challenging. This study presents an antifreeze, antibacterial, and conductive hydrogel constructed from biomacromolecules sodium carboxymethylcellulose (CMCNa) and polyvinyl alcohol (PVA). The hydrogel was synthesized via a simple one-pot method in an ethylene glycol/water (EG/H₂O) binary solvent system, incorporating lithium chloride (LiCl) and clove essential oil (CEO), followed by a single freeze-thaw cycle.
View Article and Find Full Text PDFBiology (Basel)
July 2025
Neurobiology and Molecular Medicine Unit, IRCCS Fondazione Stella Maris, Calambrone, 56128 Pisa, Italy.
Early diagnosis is critical for the effective management of neurodegenerative disorders, and retinal alterations have emerged as promising early biomarkers due to the retina's close developmental and functional link to the brain. The zebrafish (Danio rerio), with its rapid development, transparent embryos, and evolutionarily conserved visual system, represents a powerful and versatile model for studying retinal degeneration. This review discusses a range of behavioral assays-including visual adaptation, motion detection, and color discrimination-that are employed to evaluate retinal function in zebrafish.
View Article and Find Full Text PDF