A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Exploring the potential clinical value of shear wave elastography in prostate cancer: a meta-analysis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The potential role of shear wave elastography (SWE) in prostate cancer (PCa) remains unclear. We systematically searched PubMed, Web of Science, and the Cochrane Library databases to identify correlated studies up to Dec 2024. A total of 137 studies were identified for potential inclusion, and 11 studies were included, comprising 1551 PCa patients. The pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve (AUC) for detecting malignant prostatic nodules were 90% (95% CI, 81-95%), 75% (95% CI, 62-84%) and 90% (95% CI: 87, 92%) in per-patient analysis, respectively. The sensitivity, specificity, and AUC were 86% (95% CI: 72%, 95%), 86% (95% CI: 78%, 92%) and 92% (95% CI: 90%, 94%) in per-sextant analysis. Publication bias test addressed low significant small-study bias. We found that SWE may serve as a potential diagnostic strategy for PCa and may help to reduce the number of core biopsies. Since limited quantity and small sample size of included studies, further well-designed studies are strongly encouraged to address this promising strategy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12210685PMC
http://dx.doi.org/10.1186/s12885-025-14414-3DOI Listing

Publication Analysis

Top Keywords

shear wave
8
wave elastography
8
prostate cancer
8
sensitivity specificity
8
90% 95%
8
86% 95%
8
95%
7
studies
5
exploring potential
4
potential clinical
4

Similar Publications