A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluating cluster counting of Cs complexes through the study of nitrogen implanted zirconium. | LitMetric

Evaluating cluster counting of Cs complexes through the study of nitrogen implanted zirconium.

Sci Rep

Surface and Thin Films Studies Section, Surface and Sensors Studies Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102, India.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The cluster counting method (including all Cs complexes missed out in the usage of single Cs complex per element) has previously been reported to provide a significantly better composition estimate than using a single Cs complex per element, for a D9 steel sample. The current study evaluates this method with a nitrogen-implanted zirconium specimen with high oxygen impurity concentrations. Therefore, this system is prone to experiencing strong matrix effects. Quantified elemental depth profiles of the specimen were obtained using XPS to compare with SIMS results. The study confirms that cluster counting of Cs complexes yields significantly better composition estimates than the single Cs complex approach. While fluorine and chlorine are trace-level impurities, their concentrations dominate the composition estimates in both cluster counted and single Cs-complex approaches because the [Formula: see text] complexes of halogens exhibit orders of magnitude higher sensitivities than those of the other elements. Applying relative sensitivity factors of a few tens for these species renders the concentrations of these impurities insignificant. With this correction, the composition estimates by both Cs complex methods improved towards that provided by XPS. At this stage also, the match of the cluster-counted composition with the XPS estimate remains markedly better than that by the single Cs-complex estimate. Additionally, the sensitivity factor values for all cluster-counted Cs complexes were incorporated and adjusted to ensure that the elemental compositions obtained by SIMS matched exactly with those determined by XPS. These relative sensitivity factors are also provided for academic purposes, aiding future studies on secondary ion and cluster formation. Notably, a comparable match could not be achieved between the single CsX species and the XPS profiles, even when varying the sensitivity factor values for the individual CsX species. Furthermore, the cluster counting method provides a means to estimate the sputter rate at each depth of the depth profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12219416PMC
http://dx.doi.org/10.1038/s41598-025-02867-2DOI Listing

Publication Analysis

Top Keywords

cluster counting
16
single complex
12
composition estimates
12
counting complexes
8
counting method
8
complex element
8
better composition
8
single cs-complex
8
relative sensitivity
8
sensitivity factors
8

Similar Publications