A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Catheter-Vessel Interactions During Aspiration Thrombectomy: A Comprehensive Analysis Using a Novel Swine Model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Purpose: Catheter-vessel interactions during aspiration thrombectomy may vary depending on vessel size, potentially affecting reperfusion outcomes. This study aimed to assess how vessel diameter influences procedural dynamics and reperfusion success rates using a swine model with real-time, direct vessel visualization.

Materials And Methods: An animal model utilizing Yorkshire swine was used to evaluate catheter-vessel interactions during aspiration thrombectomy. The common carotid artery (CCA, 4-6 mm) and superficial cervical artery (SCA, 2-3 mm) represented large and small vessels, respectively. Each vessel was surgically exposed, occluded using clot analogs, and monitored using a high-resolution digital microscope camera. Aspiration thrombectomy was performed starting with remote aspiration, followed by contact aspiration. Vessel behavior, including collapse and traction, was evaluated in relation to vessel size and reperfusion success.

Results: A total of 33 thrombectomy procedures were performed on 14 vessels in 4 swine. In the CCA group (mean diameter: 5.14 mm), remote aspiration achieved 85.7% reperfusion success without vessel collapse, leading to 100% final reperfusion. In the SCA group (mean diameter: 2.27 mm), all remote aspiration attempts caused immediate vessel collapse with no successful reperfusion (0%), requiring contact aspiration, which resulted in 71.4% final reperfusion. Vessel collapse was significantly more frequent in SCA vs. CCA (p < 0.001). Two distinct patterns of vessel traction were observed exclusively in the SCA group.

Conclusions: Vessel size strongly influences aspiration thrombectomy efficacy. Smaller vessels are more susceptible to vessel collapse and catheter-induced traction during aspiration thrombectomy, reducing the success rate of reperfusion and increasing reliance on true contact aspiration.

Abbreviations: CCA= common carotid artery; SCA= superficial cervical artery; LVO= large-vessel occlusion.

Download full-text PDF

Source
http://dx.doi.org/10.3174/ajnr.A8898DOI Listing

Publication Analysis

Top Keywords

aspiration thrombectomy
24
vessel collapse
16
catheter-vessel interactions
12
interactions aspiration
12
vessel
12
vessel size
12
remote aspiration
12
aspiration
11
swine model
8
reperfusion
8

Similar Publications