A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

EACVI survey on evaluation and quantification of aortic regurgitation by multi-modality imaging. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: To investigate the real-world, current clinical practice of the assessment and management of aortic regurgitation (AR).

Methods And Results: An electronic survey was distributed to cardiovascular imaging specialists by the European Society Association of Cardiovascular Imaging Scientific Initiatives Committee. Three hundred respondents from 66 countries completed the survey. In patients where initial qualitative evaluation suggested moderate AR, regurgitation severity was further characterized using vena contracta in 83%, pressure half-time in 70%, jet width/outflow tract diameter in 59%, regurgitant volume/effective orifice area 57% and three-dimensional vena contract in 20% of respondents. Cardiac magnetic resonance (CMR) was used by 72% of respondents when transthoracic echocardiographic (TTE) image quality was poor and 74% of respondents when there was discordance between Doppler findings and ventricular assessments. CMR 4-dimensional flow was performed by 19% of respondents. Left ventricular (LV) diameters were measured at the mitral valve level by 52% and at the mid LV by 43% of respondents. LV volumes were measured using TTE by 70%, with CMR by 40% and with CT by 2% of respondents.

Conclusion: There is heterogeneity in the echocardiographic methods used to quantify AR. The vena-contracta is the most commonly used for assessment of AR severity with relative underutilisation of quantitative methods. CMR is widely used to assess AR severity when echocardiographic assessments are uncertain. There is variation in the anatomical location to measure LV dilatation and variable use of LV volumes which may impact decision making for intervention.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12204183PMC
http://dx.doi.org/10.1093/ehjimp/qyaf058DOI Listing

Publication Analysis

Top Keywords

aortic regurgitation
8
cardiovascular imaging
8
respondents
6
eacvi survey
4
survey evaluation
4
evaluation quantification
4
quantification aortic
4
regurgitation multi-modality
4
multi-modality imaging
4
imaging aims
4

Similar Publications