Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: To assess the workflow efficiency of an optimized MRI facility design compared to conventional facilities.
Methods: This retrospective study analyzed 7,164 non-contrast MRI examinations (3,951 knee, 2,246 shoulder, 967 ankle) performed between January 2021 and April 2024. We compared an optimized facility (OF) featuring three scanners, three dedicated preparation bays, and dockable tables to two reference facilities (RF) with traditional single-scanner/single-table setups. All scans were performed on 3 T scanners. Workflow metrics were extracted from scanner logs and electronic health records. Three-way ANOVA and chi-square tests assessed the impact of facility design, body region, and date on workflow metrics.
Results: The OF demonstrated a decrease of the mean total process cycle by 5.0-6.8 min (16.4-18.9 %) compared to RF (p < 0.001), which was primarily attributed to reduced turnaround times (mean reduction: 4.2 min, p < 0.001). Scans incorporating deep learning (DL)-based reconstruction showed 4.9-6.2 min shorter mean acquisition times at both facilities (p < 0.001). The mean time interval from patient arrival to exam start was 6.6 min shorter at OF, and on-time performance was higher at OF (79.4 %) versus RF (63.4 %) (p < 0.001).
Conclusion: This study demonstrates that optimized MRI facility design significantly enhances outpatient efficiency and increases patient throughput for non-contrast enhanced musculoskeletal examinations.
Download full-text PDF |
Source |
---|---|