Article Abstract

Soft bioelectronics mechanically comparable to living tissues have driven advances in closed-loop neuroprosthetic systems for the recovery of sensory-motor functions. Despite notable progress in this field, critical challenges persist in achieving long-term stable closed-loop neuroprostheses, particularly in preventing uncontrolled drift in the electrical sensitivity and/or charge injection performance owing to material fatigue or mechanical damage. Additionally, the absence of an intelligent feedback loop has limited the ability to fully compensate for sensory-motor function loss in nervous systems. Here, a novel class of soft, closed-loop neuroprosthetic systems is presented for long-term operation, enabled by spontaneous performance recovery and machine-learning-driven correction to address the material fatigue inherent in chronic wear or implantation environments. Central to this innovation is the development of a tough, self-healing, and stretchable bilayer material with high conductivity and exceptional cyclic durability employed for robot-interface touch sensors and peripheral-nerve-adaptive electrodes. Furthermore, two central processing units, integrated in a prosthetic robot and an artificial brain, support closed-loop artificial sensory-motor operations, ensuring accurate sensing, decision-making, and feedback stimulation processes. Through these characteristics and seamless integration, our performance-recoverable closed-loop neuroprosthesis addresses challenges associated with chronic-material-fatigue-induced malfunctions, as demonstrated by successful in vivo under 4 weeks of implantation and/or mechanical damage.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adma.202503413DOI Listing

Publication Analysis

Top Keywords

closed-loop neuroprosthetic
12
performance-recoverable closed-loop
8
neuroprosthetic systems
8
material fatigue
8
mechanical damage
8
closed-loop
5
neuroprosthetic system
4
system soft
4
soft bioelectronics
4
bioelectronics mechanically
4

Similar Publications

Conventional neuroprosthetic interfaces rely on rigid and bulky structures, which limit long-term systemic operations. For chronic applications of neural interfaces targeting regions of the nervous system (brain, spinal cord, and peripheral nerves), maintaining stable electrical performance of alternative devices without physical pressure or secondary damage to nerve tissues is important. Soft neural interfaces based on intrinsically stretchable nanocomposites, functional nanomaterials embedded in a strain-durable polymer matrix, represent ideal platforms due to their spontaneous mechanical modulus matching with biological tissues, enabling a stable device-tissue interface for high-fidelity signaling.

View Article and Find Full Text PDF

Performance-Recoverable Closed-Loop Neuroprosthetic System.

Adv Mater

June 2025

Department of Electrical and Computer Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea.

Soft bioelectronics mechanically comparable to living tissues have driven advances in closed-loop neuroprosthetic systems for the recovery of sensory-motor functions. Despite notable progress in this field, critical challenges persist in achieving long-term stable closed-loop neuroprostheses, particularly in preventing uncontrolled drift in the electrical sensitivity and/or charge injection performance owing to material fatigue or mechanical damage. Additionally, the absence of an intelligent feedback loop has limited the ability to fully compensate for sensory-motor function loss in nervous systems.

View Article and Find Full Text PDF

This perspective paper introduces a novel bidirectional framework for communication neuroprosthetics that integrates non-invasive brain stimulation (NIBS) with artificial intelligence (AI) to address both speech production and auditory processing impairments. Traditional approaches typically target only one aspect of communication, while this framework supports the complete communication cycle. The integration of transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS) with advanced AI algorithms enables the personalized, adaptive enhancement of neural signals for both speaking and listening functions.

View Article and Find Full Text PDF

The development of neuroprosthetic limbs-robotic devices designed to restore lost limb functions for individuals with limb loss or impairment-has made significant strides over the past decade, reaching the stage of successful human clinical trials. A current research focus involves providing somatosensory feedback to these devices, which was shown to improve device control performance and embodiment. However, widespread commercialization and clinical adoption of somatosensory neuroprosthetic limbs remain limited.

View Article and Find Full Text PDF

. Neural prosthetics represent a significant opportunity for control of external effectors like artificial limbs and computer devices as well as a means for interacting with virtual reality. Prior studies have shown posterior parietal cortex (PPC) to be a viable source of signals for the purposes of decoding motor intentions given its representation of both visual inputs and motor outputs.