Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
: This study evaluates and compares the diagnostic accuracy of [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007 for lymph node staging in patients with prostate cancer (PCa) scheduled for robot-assisted radical prostatectomy (RARP) and lymphadenectomy (LND). : We retrospectively reviewed prospectively collected data on patients referred to our hospital from October 2020 to January 2023. We included all patients who underwent [68Ga]Ga-PSMA-11 or [18F]F-PSMA-1007 PET/CT for primary staging and subsequently had RARP with concomitant LND. The maximum standard uptake value (SUVmax) for lymph nodes (LNs) and the SUV node-to-background ratio were reported. Two different cut-off values for the SUV node-to-background ratio (i.e., ≥2 vs. <2 and ≥15.5 vs. <15.5) were used to evaluate the diagnostic performance of both tracers. The first cut-off was empirically chosen, while the second was based on Liu's method. : A total of 156 patients were included (median age: 67 years). Among them, 83 underwent [68Ga]Ga-PSMA-11 and 73 underwent [18F]F-PSMA-1007 PET/CT. Suspicious lymph nodes were identified in 21 patients (13.5%). Pathological nodal involvement (pN1) was confirmed in 25 cases (16%). Of the 21 patients with suspicious pathological lymph nodes on PSMA PET/CT, 9 (42.9%) had positive nodes on the final pathology report. With an SUV node-to-background ratio cut-off of ≥2, [68Ga]Ga-PSMA-11 showed 37.5% sensitivity (SE) and 98.5% specificity(SP), while [18F]F-PSMA-1007 demonstrated 33.3% SE and 100% SP. Using the ≥15.5 cut-off, SE and SP were 31.3% and 100% for [68Ga]Ga-PSMA-11 and 11.1% and 100% for [18F]F-PSMA-1007, respectively. : [18F]F-PSMA-1007 PET/CT showed, even if not statistically significantly, slightly lower SE and higher SP for nodal staging compared to [68Ga]Ga-PSMA-11 PET/CT, irrespective of the SUV ratio used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12191694 | PMC |
http://dx.doi.org/10.3390/diagnostics15121492 | DOI Listing |