Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Pickleball, the fastest-growing sport in the United States, has seen a rapid increase in participation across all age groups, particularly among older adults. However, the sport introduces specific risks for ocular injuries due to the unique dynamics of gameplay and the physical properties of the pickleball. This study aims to explore the mechanisms of pickleball-related eye injuries, utilizing finite element modeling (FEM) to simulate ocular trauma and better understand injury mechanisms. A multi-modal approach was employed to investigate pickleball-related ocular injuries. Finite element modeling (FEM) was used to simulate blunt trauma to the eye caused by a pickleball. The FEM incorporated detailed anatomical models of the periorbital structures, cornea, sclera, and vitreous body, using hyperelastic material properties derived from experimental data. The simulations evaluated various impact scenarios, including changes in ball velocity, angle of impact, and material stiffness, to determine the stress distribution, peak strain, and deformation in ocular structures. The FEM outputs were correlated with clinical findings to validate the injury mechanisms. The FE analysis revealed that the rigid, hard-plastic construction of a pickleball results in concentrated stress and strain transfer to ocular structures upon impact. At velocities exceeding 30 mph, simulations showed significant corneal deformation, with peak stresses localized at the limbus and anterior sclera. Moreover, our results show a significant stress applied to lens zonules (as high as 0.35 MPa), leading to potential lens dislocation. Posterior segment deformation was also observed, with high strain levels in the retina and vitreous, consistent with clinical observations of retinal tears and vitreous hemorrhage. Validation against reported injuries confirmed the model's accuracy in predicting both mild injuries (e.g., corneal abrasions) and severe outcomes (e.g., hyphema, globe rupture). Finite element analysis provides critical insights into the biomechanical mechanisms underlying pickleball-related ocular injuries. The findings underscore the need for preventive measures, particularly among older adults, who exhibit age-related vulnerabilities. Education on the importance of wearing protective eyewear and optimizing game rules to minimize high-risk scenarios, such as close-range volleys, is essential. Further refinement of the FEM, including parametric studies and integration of protective eyewear, can guide the development of safety standards and reduce the socio-economic burden of these injuries.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12189364PMC
http://dx.doi.org/10.3390/bioengineering12060570DOI Listing

Publication Analysis

Top Keywords

finite element
16
ocular injuries
12
element analysis
8
pickleball-related eye
8
injuries
8
eye injuries
8
older adults
8
element modeling
8
modeling fem
8
fem simulate
8

Similar Publications

Impact of osteotomy angle on bone failure risk in a modified pull-through approach: a finite element analysis.

BMC Oral Health

September 2025

Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany.

Background: A modified pull-through approach represents a promising treatment strategy to access tumors in the posterior oral cavity. The design of the wedge osteotomy plays a key role in preserving postoperative mechanical stability while enabling surgical access. However, the optimal osteotomy design to reduce fracture risk remains unclear.

View Article and Find Full Text PDF

Objectives: Cervical cancer is a serious threat to women's life and health and has a high mortality rate. Colposcopy is an important method for early clinical cervical cancer screening, but the traditional vaginal dilator has problems such as discomfort in use and cumbersome operation. For this reason, this study aims to design an intelligent vaginal dilatation system to automate colposcopy and enhance patient comfort.

View Article and Find Full Text PDF

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF

Background: Drape-forming is a cost-effective method used worldwide to manufacture bespoke ankle foot orthoses (AFOs). It involves draping a heated polymer material sheet over a positive cast of the user's limb. Previous research has shown that the manual nature of drape-forming can influence the thickness of the final AFO and even lead to structures that are inadequately rigid to be clinically effective.

View Article and Find Full Text PDF

Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).

View Article and Find Full Text PDF