Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Although hippocampal-sparing whole-brain irradiation (HS-WBI) offers potential neurocognitive benefits, it poses challenges in treatment planning. This study aimed to compare the dose distributions of biaxially rotational dynamic radiation therapy (BROAD-RT) with a novel O-ring-type linear accelerator (OXRAY) and conventional non-coplanar volumetric modulated arc therapy (VMAT) planning (Conv-VMAT) in HS-WBI treatment plans. This study included 10 patients with brain metastases from lung cancer at our institution. The hippocampus was contoured using gadolinium-based contrast-enhanced magnetic resonance imaging, and hippocampal-sparing regions were created using a 5 mm margin around the hippocampus. Two virtual plans (BROAD-RT and Conv-VMAT) with 30 Gy in 10 fractions were created to compare the dose distributions in the planning target volume (PTV), hippocampus, eyes, and lens. All plans were analyzed using a paired -test. The mean (standard deviation [SD]) hippocampus-Dmax, -Dmean, -D100%, and -V10 were 11.10 (0.61), 7.95 (0.20), 7.01 (0.19), and 0.42 (0.34) for BROAD-RT and 16.10 (0.57), 9.89 (0.75), 8.24 (0.34), and 39.05 (25.89) for Conv-VMAT, respectively. All hippocampal parameters were significantly better with BROAD-RT than with Conv-VMAT ( < 0.01). The PTV-D98, -D50, -D2, -V35, and -homogeneity index did not exhibit significant differences between BROAD-RT and Conv-VMAT. Although lens-Dmax was significantly better in BROAD-RT than in Conv-VMAT ( < 0.01), no significant differences were observed in the eye-Dmax and chiasm-Dmax between BROAD-RT and Conv-VMAT. The mean (SD) BROAD-RT beam delivery time was 313.60 (34.91) s. BROAD-RT improved hippocampal sparing with acceptable PTV coverage and PTV homogeneity in HS-WBI planning. In addition, BROAD-RT has a clinically acceptable treatment duration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12190859 | PMC |
http://dx.doi.org/10.3390/cancers17121949 | DOI Listing |