A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A novel approach using a polarized nonius test to evaluate the near point of convergence. | LitMetric

A novel approach using a polarized nonius test to evaluate the near point of convergence.

J Optom

Centre for Sensors, Instruments and Systems Development (CD6). Universitat Politècnica de Catalunya - BarcelonaTech (UPC). Campus Terrassa. Rambla de Sant Nebridi, 10, 08222 Terrassa, Barcelona, Spain; Departament d'Òptica i Optometria (DOO), Universitat Politècnica de Catalunya (UPC), Campus de

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study aims to evaluate the efficacy of a new method for measuring the near point of convergence (NPC) using a Nonius polarized target stimulus, comparing its sensitivity in detecting convergence ability to that of traditional approaches.

Methods: In this prospective study, 65 participants underwent near point of convergence (NPC) measurements using three methods: an accommodative target (NPC1), a penlight with a red filter (NPC2), and a Nonius polarized target (NPC3). Participants also completed the Convergence Insufficiency Symptom Survey (CISS). Statistical analyses, including repeated-measures ANOVA and Spearman's correlation, were conducted to assess differences among the methods.

Results: The Nonius method demonstrated a median break point of 8.37 cm, significantly higher than the other methods, NPC1: 6.63 cm, and NPC2: 7.17 cm. Sensitivity for detecting CI symptoms was 92.6 % for the NPC3, which outperformed NPC1 (77.8 %) and NPC2 (74.1 %). NPC3 exhibited low specificity (7.4 %). Correlations between NPC measurements and CISS scores were weak and nonsignificant, though the strongest correlation was observed for NPC3 CONCLUSION: The Nonius polarized target method shows benefits compared to traditional methods in measuring NPC. This study provides a more sensitive method to measure convergence ability, reducing variability across clinical settings, and enhancing the reliability of assessments in both research and practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12205783PMC
http://dx.doi.org/10.1016/j.optom.2025.100563DOI Listing

Publication Analysis

Top Keywords

point convergence
12
nonius polarized
12
polarized target
12
convergence npc
8
sensitivity detecting
8
convergence ability
8
npc measurements
8
convergence
6
nonius
5
novel approach
4

Similar Publications