A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of Warmer Height (Standard versus Custom) on Neonatal Chest Compression Performance: A Cross-Over Simulation Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study aimed to evaluate whether a custom warmer height improves the quality and consistency of chest compressions (CCs) compared with a standard warmer height during simulated neonatal resuscitation.Cross-over study using simulated neonatal resuscitation. A controlled research environment equipped with a 12-camera motion capture system, four in-floor multi-axis force plates, a neonatal manikin, and resuscitation equipment. Biomechanical assessments were recorded every 2 minutes during a 20-minute simulation for each condition. Twenty Neonatal Resuscitation Program (NRP)-trained providers. Each participant performed two 20-minute CC sessions-one with the warmer at the standard 100 cm height and one at a custom height selected by the participant. CC depth, force, and rate; participant back angle, heart rate, and self-reported exertion, were analyzed at 2-minute intervals.Compared with the standard height, the custom height resulted in greater and more consistent CC depth and force while maintaining compression rate. Participants also exhibited a greater back angle, and lower heart rate, and reported reduced exertion under the custom height condition.Allowing NRP-trained providers to adjust warmer heights led to improved CC quality and consistency, suggesting that customizable warmer heights may enhance neonatal resuscitation performance. KEY POINTS: · Custom warmer height chosen by NRP-trained providers resulted in more consistent and greater CC depth and force.. · It also was associated with less provider fatigue, compared with standard height.. · During neonatal resuscitation, frontline healthcare professionals changed.. · Participant heart rate was lower when using the custom versus standard height.. · Our findings support the need for guidelines on adjusting warmer height during neonatal cardiopulmonary resuscitation..

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2620-7882DOI Listing

Publication Analysis

Top Keywords

warmer height
20
neonatal resuscitation
16
nrp-trained providers
12
custom height
12
depth force
12
heart rate
12
standard height
12
height
11
warmer
8
neonatal
8

Similar Publications