Article Abstract

BackgroundThe first-pass effect (FPE) refers to the complete or near-complete revascularization with a single pass of mechanical thrombectomy devices. While previous claims suggest a link between larger catheters and the effectiveness of contact aspiration (CA) thrombectomy, no extensive research has confirmed if larger distal inner diameter (ID) catheters achieve higher FPE rates.MethodsWe searched PubMed, Scopus, and Web of Science to assess the impact of aspiration catheter distal ID size on FPE. The primary outcome was FPE rate, defined as thrombolysis in cerebral ischemia (TICI) grades 2c-3 at first pass, and the secondary outcome was modified FPE (TICI 2b-3 in a single pass). Aspiration catheters were categorized based on distal ID: 0.060-0.069 (medium bore), 0.070-0.074 (large bore), and greater than 0.074 inches (super-large bore). Rates of FPE were pooled using random effect models and compared using a Chi-square test.ResultsOur study included 34 articles with 4831 patients. FPE rates were 27.7% (95% CI, 15.1-45.3) for medium bore, 46.6% (95% CI, 33.7-59.9) for large, and 58.3% (95% CI, 44.8-70.7) for super-large catheters. The FPE rate was significantly higher for super-large bore catheters compared with other groups (χ² = 7.26, p = 0.03). A similar trend was observed for modified FPE rates, which were 51.1% (95% CI, 45.3-56.8) for medium bore, 60.0% (95% CI, 52.8-66.8) for large bore, and 80% (95% CI, 56.3-94.2) for super-large bore catheters (χ² = 8.14, p = 0.03).ConclusionOur analysis indicates that larger CA catheters are correlated with higher FPE rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12152002PMC
http://dx.doi.org/10.1177/15910199251345637DOI Listing

Publication Analysis

Top Keywords

medium bore
12
super-large bore
12
fpe rates
12
fpe
10
impact aspiration
8
aspiration catheter
8
inner diameter
8
single pass
8
larger catheters
8
higher fpe
8

Similar Publications

We aimed to assess the associations between pre-treatment personality traits on symptoms of posttraumatic stress disorder (PTSD) and depression before and after an intensive outpatient treatment program (IOP). In a secondary data analysis of a sample of  = 665 veteran or active-duty U.S.

View Article and Find Full Text PDF

BackgroundThe first-pass effect (FPE) refers to the complete or near-complete revascularization with a single pass of mechanical thrombectomy devices. While previous claims suggest a link between larger catheters and the effectiveness of contact aspiration (CA) thrombectomy, no extensive research has confirmed if larger distal inner diameter (ID) catheters achieve higher FPE rates.MethodsWe searched PubMed, Scopus, and Web of Science to assess the impact of aspiration catheter distal ID size on FPE.

View Article and Find Full Text PDF

Introduction: While revascularization rates have improved for mechanical thrombectomy (MT) in acute ischemic stroke, advancements in aspiration pumps have been limited. The ALGO Smart Pump (Von Vascular, Sunrise, FL) is a small on-field, operator-driven pump offering two aspiration modes: Adaptive Pulsatile Aspiration (APA™) Mode and a continuous 'Static' mode. This study evaluates the performance of the ALGO Smart Pump's Static Mode compared to a commercially available aspiration pump.

View Article and Find Full Text PDF

Accidental vascular catheter removal (AVCR) by patients with cognitive impairment can result in loss of access for infusion therapy, significant blood loss, air embolism with large bore catheters, and withholding life-sustaining dialysis treatment. Chest-to-back (CTB) tunneling of central venous catheters is a technique described in the Rapid Assessment of Vascular Access Exit Site and Tunneling Options (RAVESTO) for patients at risk for AVCR. In this retrospective review, data was collected for all venous access devices inserted using CTB tunneling in patients requiring medium to long term intravenous access for infusion or hemodialysis, who had a history of self-removing medical devices due to an alteration in mental status, or patients with severely impaired skin integrity.

View Article and Find Full Text PDF