A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Performance of Computer-Aided Detection Software in Tuberculosis Case Finding in Township Health Centers in China. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Computer-aided detection (CAD) software has been introduced to automatically interpret digital chest X-rays. This study aimed to evaluate the performance of CAD software (JF CXR-1 v3.0, which was developed by a domestic Hi-tech enterprise) in tuberculosis (TB) case finding in China.

Methods: In 2019, we conducted an internal evaluation of the performance of JF CXR-1 v3.0 by reading standard images annotated by a panel of experts. In 2020, using the reading results of chest X-rays by a panel of experts as the reference standard, we conducted an on-site prospective study to evaluate the performance of JF CXR-1 v3.0 and local radiologists in TB case finding in 13 township health centers in Zhongmu County, Henan Province.

Results: Internal assessment results based on 277 standard images showed that JF CXR-1 v3.0 had a sensitivity of 85.94% (95% confidence interval [CI]: 77.42%, 94.45%) and a specificity of 74.65% (95% CI: 68.81%, 80.49%) to distinguish active TB from other imaging conditions. In the on-site evaluation phase, images from 3705 outpatients who underwent chest X-ray detection were read by JF CXR-1 v3.0 and local radiologists in parallel. The imaging diagnosis of local radiologists for active TB had a sensitivity of 32.89% (95% CI: 22.33%, 43.46%) and a specificity of 99.28% (95% CI: 99.01%, 99.56%), while JF CXR-1 v3.0 showed a significantly higher sensitivity of 92.11% (95% CI: 86.04%, 98.17%) ( < 0.05) and maintained high specificity at 94.54% (95% CI: 93.81%, 95.28%).

Conclusions: CAD software could play a positive role in improving the TB case finding capability of township health centers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12142701PMC
http://dx.doi.org/10.1002/cdt3.70001DOI Listing

Publication Analysis

Top Keywords

cxr-1 v30
24
case finding
12
local radiologists
12
computer-aided detection
8
tuberculosis case
8
finding township
8
township health
8
health centers
8
cad software
8
chest x-rays
8