A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Validity and reliability of single camera markerless motion capture systems with RGB-D sensors for measuring shoulder range-of-motion: a systematic review. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Assessing shoulder joint range-of-motion (ROM) is crucial for evaluating shoulder mobility but remains challenging due to its complexity. This review examined the potential of single-camera markerless motion capture systems with an RGB-depth (RGB-D) sensor for shoulder ROM measurements, focusing on their reliability and validity.

Methods: We systematically searched nine databases through December 2022 for studies that evaluated the reliability and validity of single-camera markerless motion-capture systems in measuring simple (one-directional) and complex (multi-directional) shoulder movements. We extracted data on participant characteristics, device details, and measurement outcomes, and then assessed the methodological quality using the Consensus-Based Standards for the Selection of Health.

Results: Of the 2,976 articles identified, 14 were included in this review. The findings indicate that intra-rater reliability findings across six studies were inconsistent, with simple movements like abduction and flexion demonstrating better reliability and less heterogeneity compared to complex movements. Validity assessments across 12 studies also showed inconsistency, with abduction and flexion measurements exhibiting higher validity than rotational movements. Studies focusing on simple movements reported good to excellent validity, particularly for abduction and flexion. Quality assessments using the COSMIN checklist revealed that the methodological quality varied across studies, ranging from inadequate to very good.

Discussion: This systematic review suggests that RGB-D sensors show promise for measuring shoulder joint ROM, especially in simple movements like flexion and abduction. However, complex movements and inconsistencies limit their immediate clinical applicability, necessitating further high-quality research with advanced devices to ensure accurate and reliable assessments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12141239PMC
http://dx.doi.org/10.3389/fbioe.2025.1570637DOI Listing

Publication Analysis

Top Keywords

simple movements
12
abduction flexion
12
markerless motion
8
motion capture
8
capture systems
8
rgb-d sensors
8
measuring shoulder
8
systematic review
8
shoulder joint
8
single-camera markerless
8

Similar Publications