Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Upper limb loss can negatively impact an individual's ability to perform daily tasks as well as mental health and well-being. Currently available prosthetic control interfaces provide limited prosthetic finger dexterity compared to the complex functions that multi-articulating robotic hands are capable of actuating. A significant barrier is the ability to reliably sense efferent motor action potentials from peripheral nerves when a patient's muscles are lost or damaged due to amputation and injury. In an early-feasibility clinical trial, we implanted four patients with intramuscular electrodes in Regenerative Peripheral Nerve Interfaces (RPNIs). In all patients, the electrodes recorded large-amplitude and stable control signals from RPNIs with a median Signal-to-Noise Ratio (SNR) of 40.6 throughout their study participation. No serious adverse events occurred related to the electrode implantation or the devices themselves. Furthermore, implanting RPNIs provided valuable information to create an algorithm to predict movements previously mediated by lost muscles. These results indicate RPNI-electrode implantation is a repeatable and viable technique to record nerve signals for prosthetic control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12136193PMC
http://dx.doi.org/10.21203/rs.3.rs-5989030/v1DOI Listing

Publication Analysis

Top Keywords

prosthetic control
8
robust neuromuscular
4
neuromuscular interface
4
interface restore
4
restore lost
4
lost function
4
function people
4
people amputations
4
amputations upper
4
upper limb
4

Similar Publications

Statement Of Problem: Although custom temporomandibular joint (TMJ) prostheses manufactured via computer-aided design and manufacturing (CAD-CAM) and produced through 3-dimensional (3D) printing or computer numerical control (CNC) allow for sagittal curvature adjustments in the glenoid fossa, their design remains unregulated by the Food and Drug Administration. Consequently, the geometry is determined largely by the engineer's discretion, with limited biomechanical evidence to guide these decisions. The lack of validation regarding how sagittal curvature influences joint stress distribution under various anatomical and functional conditions represents a gap in current knowledge that warrants investigation.

View Article and Find Full Text PDF

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary noninvasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered.

View Article and Find Full Text PDF

Self-supervised representation learning with continuous training data improves the feel and performance of myoelectric control.

Comput Biol Med

September 2025

Department of Electrical and Computer Engineering and the Institute of Biomedical Engineering, University of New Brunswick, Fredericton, E3B 5A3, NB, Canada.

Pattern recognition-based myoelectric control is traditionally trained with static or ramp contractions, but this fails to capture the dynamic nature of real-world movements. This study investigated the benefits of training classifiers with continuous dynamic data, encompassing transitions between various movement classes. We employed both conventional (LDA) and deep learning (LSTM) classifiers, comparing their performance when trained with ramp data, continuous dynamic data, and an LSTM pre-trained with a self-supervised learning technique (VICReg).

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.

Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.

View Article and Find Full Text PDF

With increasing antibiotic resistance and the paucity of new antibiotics in the development pipeline, exploration of antimicrobial peptide applications alone or in combination with existing antibiotics is more crucial than ever. The recent study by J. Varin-Simon, E.

View Article and Find Full Text PDF