A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Microneedle Arrays for Near-Infrared-Controlled Insulin Delivery Based on Thermosensitive Microgel. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Insulin delivery plays a crucial role in diabetic treatment. Regular painless administration methods are not ideal for insulin delivery due to their insufficient bioavailability and inefficiency. In this study, dissolving microneedle array patches containing a thermosensitive insulin carrier P(NIPAm-AAm) microgel (MG) and the photothermal agent MXene were prepared with drug-protected protocols for near-infrared (NIR) light-controlled painless and minimally invasive insulin delivery. The microneedles (Ins-MG/MXene-HA-MNs) can penetrate the stratum corneum, rapidly heat to above 42 °C in 10 s, and promote the release of insulin in an instant response to NIR light exposure. and experiments showed that Ins-MG/MXene-HA-MNs were biocompatible and efficient. Using one microneedle array patch and two brief NIR exposures can ensure effective insulin blood levels and maintain normoglycemia in rats for over 6 h at high glucose levels. Additionally, the fabrication and application of this drug delivery system have been designed to protect insulin bioactivity. The results showed that the MG/MXene-HA-MN array patch realized NIR-controlled multiple on-demand insulin dosing, highlighting its potential for routine blood glucose management.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.5c03807DOI Listing

Publication Analysis

Top Keywords

insulin delivery
16
insulin
9
microneedle array
8
array patch
8
delivery
5
microneedle arrays
4
arrays near-infrared-controlled
4
near-infrared-controlled insulin
4
delivery based
4
based thermosensitive
4

Similar Publications