Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Upper reference values for thyroid volume are 25 mL for men and 18 mL for women. Thyroid volume alters with age, body weight, body height, and iodine status, which is not considered in the current limits. The aim was to develop reference equations, considering age, body weight, and height to calculate individual reference values for thyroid volume.

Design: This cross-sectional study used data from 3 independent cohorts (SHIP-START, SHIP-TREND, and KORA-F4) in Germany. SHIP-START-0, a population-based health survey, was carried out in Northern Germany, from 1997 to 2001. SHIP-TREND-0, a second independent sample of the same study region, was carried out between 2008 and 2012. KORA-F4, a population-based health survey, was conducted between 2006 and 2008 in Southern Germany.

Methods: A total of 11 549 individuals (51% women) were included in the data analysis. Eight thousand six-hundred and six individuals (45% women) were used as the thyroid-healthy reference population when developing equations. Sex-stratified quantile regression models for the 95th percentile using age, body weight, and height as explanatory variables were performed.

Results: The overall reference value was 38.7 mL for men and 28.6 mL for women. According to the established cut-offs, 34% of the overall population would have had goitre compared with 7% when using our equations.

Conclusion: Upper reference values for thyroid volume are too low for an adult, previously iodine-deficient population and do not consider age, body weight, and height. Using individualised equations reduces the prevalence of thyroid enlargement substantially and can lead to a decrease in overdiagnoses and the use of medical resources.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejendo/lvaf108DOI Listing

Publication Analysis

Top Keywords

reference values
16
age body
16
body weight
16
values thyroid
12
thyroid volume
12
weight height
12
thyroid enlargement
8
upper reference
8
population-based health
8
health survey
8

Similar Publications

Background: Interstitial lung disease (ILD) is a significant cause of morbidity and mortality in systemic sclerosis (SSc), particularly among Black patients. Pulmonary function tests (PFTs) are critical to screen for and monitor SSc-ILD. We examined whether race-specific and race-neutral PFT reference equations impact classification of restrictive lung disease (RLD) severity in Black and White patients with SSc.

View Article and Find Full Text PDF

The aim of this study was to propose reference values for the Dynamic Evaluation Method of Lower Limb Joint Alignment (MADAAMI II). During the 2023 Joinville Dance Festival, 346 dancers (315 females and 31 males), aged between 15 and 58 years, with a minimum of 5 years of ballet experience, were randomly evaluated. The dancers were filmed performing the three-step sequence (demi plié, grand plié, and fondu) of the MADAAMI II, in the first foot position, with self-selected turnout and at 120 degrees.

View Article and Find Full Text PDF

Purpose: To develop and validate a fast, motion-robust, free-breathing abdominal 3D T1ρ mapping method by combining variable-density diamond radial k-space sampling with fast-MAPSS (magnetization-prepared angle-modulated partitioned-k-space spoiled gradient-echo snapshots).

Methods: 3D MAPSS T1ρ imaging was performed at 3T using five spin-lock time (TSL) pairs in phantom scans and three TSL pairs in nine healthy volunteers. Phantom experiments compared Cartesian sampling (reference) with stack-of-stars and diamond radial sampling.

View Article and Find Full Text PDF

Background: Echocardiographic reference intervals for Quarter Horses are infrequently reported.

Objectives: To provide standard echocardiographic measurements for sedentary Quarter Horses and evaluate the relationship between physical characteristics (body weight, age, sex) and echocardiographic measurements.

Animals: Forty-one sedentary Quarter Horses, free of cardiac disease, from a university research herd.

View Article and Find Full Text PDF

Automated Facial Aesthetics Evaluation: Performance of the Beauty Scanner-Face Analyzer in Measuring Symmetry and Proportions.

Aesthetic Plast Surg

September 2025

Department of Plastic and Cosmetic Surgery, Tongji Hospital, School of Medicine, Tongji University, No.389 Xincun Road, Shanghai, 200092, China.

Background: The integration of digital tools in aesthetic medicine has enhanced the precision of facial feature analysis. Using concepts like the Golden Ratio, these technologies enable more objective assessments of facial proportions and symmetry. The beauty scanner-face analyzer (BS-FA) app offers a digital approach to evaluate geometric proportions and facial alignment, providing valuable data for preoperative planning in plastic surgery and aesthetic treatments.

View Article and Find Full Text PDF