Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Recent advancements in digital pathology have extended into cytopathology. Laboratories screening cervical cytology specimens now choose between limited imaging options and traditional manual microscopy. The Techcyte SureView™ Cervical Cytology System, designed for digital cytopathology, was validated at CorePlus, a pathology laboratory in Puerto Rico, and adopted as a 100% quality control (QC) tool.
Methods: The validation study included 1442 whole slide images (WSIs) from 1273 ThinPrep® and 169 SurePath™ cervical cytology slides, digitized with the 3DHISTECH Panoramic 1000 DX scanner using dry and water immersion scanning profiles. These WSIs were processed by the Techcyte SureView™ system, with a board-certified cytopathologist reviewing artificial intelligence (AI)-identified objects of interest and comparing them to traditional light microscopy results.
Results: Techcyte SureView™ with the water immersion scanning profile outperformed both the dry scanning profile and light microscopy in detecting squamous and glandular abnormalities. It achieved 97% accuracy, 82% sensitivity, 99% specificity, 98% negative predictive value, and 86% positive predictive value. Additionally, the review time was rapid. The system has been operational for several months, enhancing accuracy and workflow efficiency.
Conclusions: This study demonstrates that digital cytopathology, particularly through the Techcyte SureView™ system, can improve laboratory workflow and performance. Successful validation led CorePlus to integrate the AI algorithm into their workflow as a 100% QC review tool, resulting in improved accuracy, benefiting both laboratory professionals and patients.