Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The effectiveness of hard orthokeratology (OK) lenses in controlling myopia has been confirmed in clinical practice. However, there exist defects including wear discomfort, limited regulation of mechanical properties and geometry, and effectiveness inconsistency with the expected efficacy. Herein, we analyze the relationship between the mechanical properties of OK lenses and the vertex displacement of the human cornea through the finite element model. It is noted that the expected corneal deformation of 15-20 μm can be achieved by soft OK lenses with an elasticity modulus above 9 MPa, which is far lower than the 2.7 GPa of commercial OK lenses. No obvious displacement difference occurred when the elasticity modulus of the OK lenses exceeded 200 MPa. Thus, we propose the hypothesis of soft OK lenses based on hydrogel materials for controlling myopia. The soft OK lenses are fabricated by a two-step 3D printing technology using a multicomponent bioink containing methyl methacrylate, hydroxyethyl methacrylate, polyethylene glycol diacrylate, and 3-(trimethoxysilyl)propyl methacrylate (KH-570). The printed OK lenses possess comfort wear, high light transmittance, smooth surface, regulated elasticity modulus (from 33 to 535 MPa) and geometry, and excellent biocompatibility. Additionally, the effectiveness of soft OK lenses is confirmed through a porcine corneal model with obvious corneal deformation comparable to that of the commercial ones. This study demonstrates the feasibility of soft OK lenses for controlling myopia and provides support for the design and fabrication of soft OK lenses for comfortable wear.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.5c03402 | DOI Listing |