A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design and 3D Printing of Soft Orthokeratology Lenses. | LitMetric

Design and 3D Printing of Soft Orthokeratology Lenses.

ACS Appl Mater Interfaces

Institute of Applied Mechanics, College of Aeronautics and Astronautics, Taiyuan University of Technology, Taiyuan 030024, China.

Published: May 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The effectiveness of hard orthokeratology (OK) lenses in controlling myopia has been confirmed in clinical practice. However, there exist defects including wear discomfort, limited regulation of mechanical properties and geometry, and effectiveness inconsistency with the expected efficacy. Herein, we analyze the relationship between the mechanical properties of OK lenses and the vertex displacement of the human cornea through the finite element model. It is noted that the expected corneal deformation of 15-20 μm can be achieved by soft OK lenses with an elasticity modulus above 9 MPa, which is far lower than the 2.7 GPa of commercial OK lenses. No obvious displacement difference occurred when the elasticity modulus of the OK lenses exceeded 200 MPa. Thus, we propose the hypothesis of soft OK lenses based on hydrogel materials for controlling myopia. The soft OK lenses are fabricated by a two-step 3D printing technology using a multicomponent bioink containing methyl methacrylate, hydroxyethyl methacrylate, polyethylene glycol diacrylate, and 3-(trimethoxysilyl)propyl methacrylate (KH-570). The printed OK lenses possess comfort wear, high light transmittance, smooth surface, regulated elasticity modulus (from 33 to 535 MPa) and geometry, and excellent biocompatibility. Additionally, the effectiveness of soft OK lenses is confirmed through a porcine corneal model with obvious corneal deformation comparable to that of the commercial ones. This study demonstrates the feasibility of soft OK lenses for controlling myopia and provides support for the design and fabrication of soft OK lenses for comfortable wear.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.5c03402DOI Listing

Publication Analysis

Top Keywords

soft lenses
24
lenses
12
controlling myopia
12
elasticity modulus
12
orthokeratology lenses
8
lenses controlling
8
mechanical properties
8
corneal deformation
8
soft
7
design printing
4

Similar Publications