Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Recent studies have shown that cardiac substructures and particularly left anterior descending artery (LAD) dose strongly correlates with the incidence of late adverse cardiac events. We evaluated whether greater cardiac and, importantly, LAD dose sparing could be achieved using a newly introduced closed bore (O-ring gantry) linac with a double-stacked multileaf collimator (Varian Ethos) relative to conventional linacs.

Methods And Materials: Twenty patients with locally advanced non-small cell lung cancer previously treated with definitive chemoradiotherapy were retrospectively evaluated. Volumetric modulated arc therapy plans were retrospectively generated for the Ethos system using optimization criteria focused on reducing overall heart and LAD doses (Heart_Ethos). Plans were also reoptimized using the same optimization criteria on a conventional C-arm linac (Heart_TB). Investigational plans were compared with the original plans and with each other using standard dose-volume histogram metrics such as percentage (V) volume receiving a specific dose (x) in Gy (Vx) or mean dose (Dmean) in Gy.

Results: Statistically significant decreases existed between the Heart_Ethos and original plans for mean heart dose (11.3 vs 14.8 Gy; < .001) and V5, V30, and V50 (63.6% vs 75.2%; < .001, 7.1% vs 12.3%; < .001, 2.1% vs 2.9%; = .03, respectively) and also for LAD mean dose (4.8 Gy vs 12.0 Gy [ < .001]) and V15 (4.9% vs 21.5%; < .001). Compared with Heart_TB, Heart_Ethos plans had significantly less mean heart dose (11.6 vs 12.2 Gy; = .006), and less heart V5 (64.4% vs 67.2%; = .049) and V30 (7.7% vs 8.8%; = .03), whereas other parameters were not significant. Optimal target coverage and other organs at risk constraints were maintained for all generated plans.

Conclusions: Heart_Ethos plans showed significant reduction in cardiac and LAD doses in comparison to the original plans while maintaining target and organ at risk goals. Our findings suggest that Ethos technology has the potential for better cardiac toxicity safety because Heart_Ethos plans were still able to reduce cardiac dose compared with Heart_TB plans.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12076829PMC
http://dx.doi.org/10.1016/j.adro.2025.101779DOI Listing

Publication Analysis

Top Keywords

heart_ethos plans
16
lad dose
12
original plans
12
plans
10
left anterior
8
anterior descending
8
descending artery
8
patients locally
8
locally advanced
8
lung cancer
8

Similar Publications

Background And Purpose: Chemoradiotherapy (CRT) followed by surgery is a treatment option for esophageal cancer (EC). However, concerns persist regarding cardiopulmonary toxicity and inconsistent daily target coverage due to anatomical changes. To address these challenges, we implemented a CBCT-based online adaptive radiotherapy (oART) workflow for EC.

View Article and Find Full Text PDF

Purpose: Recent studies have shown that cardiac substructures and particularly left anterior descending artery (LAD) dose strongly correlates with the incidence of late adverse cardiac events. We evaluated whether greater cardiac and, importantly, LAD dose sparing could be achieved using a newly introduced closed bore (O-ring gantry) linac with a double-stacked multileaf collimator (Varian Ethos) relative to conventional linacs.

Methods And Materials: Twenty patients with locally advanced non-small cell lung cancer previously treated with definitive chemoradiotherapy were retrospectively evaluated.

View Article and Find Full Text PDF

Purpose: Online adaptive radiation therapy (oART) has shown the ability to diminish interfraction variations. However, oART is a time- and labor-intensive process, and the optimal adaptation frequency remains to be determined for lung cancer oART. The purpose of this study was to quantify and assess dosimetric benefits associated with various adaptive frequencies in patients with lung cancer receiving oART.

View Article and Find Full Text PDF

Introduction: Following a preliminary work validating the technological feasibility of an adaptive workflow with Ethos for whole-breast cancer, this study aims to clinically evaluate the automatic segmentation generated by Ethos.

Material And Methods: Twenty patients initially treated on a TrueBeam accelerator for different breast cancer indications (right/left, lumpectomy/mastectomy) were replanned using the Ethos emulator. The adaptive workflow was performed using 5 randomly selected extended CBCTs per patient.

View Article and Find Full Text PDF

Purpose: Radiation therapy (RT) plays a key role in the management of esophageal cancer (EC). However, toxicities caused by proximity of organs at risk (OAR) and daily target coverage caused by interfractional anatomic changes are of concern. Daily online adaptive RT (oART) addresses these concerns and has the potential to increase OAR sparing and improve target coverage.

View Article and Find Full Text PDF