Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Real-time monitoring of sweat lactate provides valuable physiological insights for assessing exercise outcomes and athletic performance. Conventional lactate detection methods, while sensitive, often lack portability and real-time capability for use in wearable or in-body applications. To address these limitations, electrochemical biosensing has emerged as a leading approach, enabling non-invasive and real-time analysis. Wearable devices which integrate lactate-specific enzymes with electrochemical transducers might provide efficient solutions for continuous monitoring. In this study, a wearable lactate biosensor was developed using custom screen-printed electrodes modified with a bio-hybrid probe comprising Prussian blue, carbon black, and lactate oxidase. All the key experimental parameters were optimized, and a detection limit of 60 µM and a linearity up to 20 mM were obtained. A filter paper-based strip was incorporated to enhance sweat collection and serve as the real sample collector by exploiting its porosity: this configuration allowed a satisfactory repeatability of 6%. The system was validated using real sweat samples, highlighting a quantitative correlation (94-103%) with LC-MS/MS measurements. The biosensor was integrated onto a 3D-printed thermoplastic polyurethane (TPU) armband, designed for a customizable and comfortable fit, ensuring effective sweat collection and transport. This low-cost, wearable system represents a significant step forward in non-invasive, continuous, and personalized health monitoring, providing a practical tool for tracking physiological parameters in real-time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12227461 | PMC |
http://dx.doi.org/10.1007/s00216-025-05905-0 | DOI Listing |