A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An optimized shunt active power filter using the golden Jackal optimizer for power quality improvement. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Integration of nonlinear loads in modern power systems has led to many issues arising mainly due to the generation of harmonic currents and the presence of reactive power, both having adverse effects on power quality and grid stability. Harmonic currents cause increased losses, overheating of equipment, and voltage distortions, while reactive power imbalances result in inefficiencies in power delivery and compromised system performance. To overcome these problems, a Shunt Active Power FIlter design and an optimal control strategy for harmonic mitigation and reactive power compensation are proposed in this paper. The design incorporates an optimized anti-windup PI controller for DC-link voltage regulation and an optimized output filter to enhance the quality of the injected current. This design is formulated as an optimization problem and solved using the Golden Jackal Optimizer. MATLAB/Simulink simulations validate the proposed method under different operating conditions, covering dynamic change of loads and unbalanced grid conditions. The result shows a remarkable reduction in Total Harmonic Distortion (THD) of grid current, and reactive power compensation meanwhile maintaining the stability of the grid.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12059022PMC
http://dx.doi.org/10.1038/s41598-025-00204-1DOI Listing

Publication Analysis

Top Keywords

reactive power
16
power
10
shunt active
8
active power
8
power filter
8
golden jackal
8
jackal optimizer
8
power quality
8
harmonic currents
8
power compensation
8

Similar Publications