Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: The present study focused on evaluating and comparing the stresses and displacements generated by various designs of miniscrew-assisted maxillary expansion appliances. The primary focus of this study is on a modified design for treating unilateral maxillary constriction, analyzed using the finite element method (FEM).
Materials And Methods: Using computed tomography (CT) scans and the modeling software Mimics, a three-dimensional (3D) mesh model of the skull and related maxillary structures was created. First, the necessary material characteristics were determined using FEM. Three models of miniscrew-assisted maxillary expansion appliances were then tested with ANSYS simulation software: (a) a bone-anchored rapid palatal expander (BARPE), (b) a conventional miniscrew-assisted rapid palatal expansion (C-MARPE), and (c) an asymmetric design of a MARPE focusing on unilateral expansion (U-MARPE). The asymmetric U-MARPE design features an attachment connecting the expander to the teeth on only one half of the maxilla. The stress, displacement, and distribution predictions for all three types of expanders were subsequently evaluated via FEM.
Results: Tooth displacement in the U-MARPE (on the expander-to-tooth attachment side) and C-MARPE groups was greater than that in the BARPE group. The stresses on the teeth were lowest in the BARPE and U-MARPE groups (on the expander-to-no-tooth attachment side). C-MARPE exhibited a symmetrical stress distribution around the miniscrew areas. Overall, U-MARPE generated the greatest amount of asymmetric von Mises stress and displacement on the dental landmarks.
Conclusion: This research indicates that, compared to other models, U-MARPE achieves more favorable unilateral expansion effects. The current U-MARPE design can be effectively used to correct unilateral transverse anomalies.