Background: Many patients are instructed to fast before abdominal ultrasound examinations in order to obtain better image quality. However, the few available studies on this topic have so far failed to demonstrate an advantage of several hours of fasting. Prolonged fasting can lead to patient distress, hypoglycemia (e.g. in insulin-treated patients), and malnutrition. Therefore, unnecessary fasting should be avoided.
Methods: For this prospective investigator-blinded study, we recruited 250 inpatients who were registered for abdominal ultrasonography in our hospital and randomized them into one of three groups: fasting for several hours, regular breakfast, or a liquid oral nutritional supplement. 215 patients could be evaluated. The sonographies were performed consecutively by inexperienced and experienced examiners who independently rated the image quality of seven anatomical structures (gallbladder, common hepatic duct [i.e., proximal part of the common duct], common bile duct [i.e., distal part of the common duct], pancreatic head, pancreatic body, pancreatic tail, and origin of the superior mesenteric artery) on a Likert scale from 1 to 5. The mean of these scores was calculated as a parameter for the diagnostic quality of the abdominal ultrasound examination.
Results: No significant difference was found for sonographic image quality after eating breakfast vs. fasting in both experienced and inexperienced examiners. In inexperienced examiners, image quality was rated slightly better after intake of liquid nutritional supplements compared to a normal breakfast (p = 0.023) or fasting (p = 0.047). However, the effect size was small.
Conclusion: A general recommendation for several hours of fasting before abdominal sonography is not necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00261-025-04947-3 | DOI Listing |
Circ Arrhythm Electrophysiol
September 2025
Department of Congenital Heart Disease, Evelina London Children's Hospital, United Kingdom (S. Chivers, T.V., V.Z., S.M., G.M., W.R., E.R., D.F.A.L., T.G.D., O.I.M., G.K.S., J.M.S.).
Background: Fetal tachycardias can cause adverse fetal outcomes including ventricular dysfunction, hydrops, and fetal demise. Postnatally, ECG is the gold standard, but, in fetal practice, echocardiography is used most frequently to diagnose and monitor fetal arrhythmias. Noninvasive extraction of the fetal ECG (fECG) may provide additional information about the electrophysiological mechanism and monitoring of intermittent arrhythmias.
View Article and Find Full Text PDFACS Sens
September 2025
Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan.
In recent AI-driven disease diagnosis, the success of models has depended mainly on extensive data sets and advanced algorithms. However, creating traditional data sets for rare or emerging diseases presents significant challenges. To address this issue, this study introduces a direct-self-attention Wasserstein generative adversarial network (DSAWGAN) designed to improve diagnostic capabilities in infectious diseases with limited data availability.
View Article and Find Full Text PDFMagn Reson Med
September 2025
Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
Purpose: To develop a deep learning-based reconstruction method for highly accelerated 3D time-of-flight MRA (TOF-MRA) that achieves high-quality reconstruction with robust generalization using extremely limited acquired raw data, addressing the challenge of time-consuming acquisition of high-resolution, whole-head angiograms.
Methods: A novel few-shot learning-based reconstruction framework is proposed, featuring a 3D variational network specifically designed for 3D TOF-MRA that is pre-trained on simulated complex-valued, multi-coil raw k-space datasets synthesized from diverse open-source magnitude images and fine-tuned using only two single-slab experimentally acquired datasets. The proposed approach was evaluated against existing methods on acquired retrospectively undersampled in vivo k-space data from five healthy volunteers and on prospectively undersampled data from two additional subjects.
MAGMA
September 2025
Department of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.
Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.
Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.
J Cancer Res Clin Oncol
September 2025
Department of Radiology, Guizhou Provincial People's Hospital, No. 83 East Zhongshan Road, Guiyang, 550002, Guizhou, China.
Purpose: Targeted therapy with lenvatinib is a preferred option for advanced hepatocellular carcinoma, however, predicting its efficacy remains challenging. This study aimed to build a nomogram integrating clinicoradiological indicators and radiomics features to predict the response to lenvatinib in patients with hepatocellular carcinoma.
Methods: This study included 211 patients with hepatocellular carcinoma from two centers, who were allocated into the training (107 patients), internal test (46 patients) and external test set(58 patients).