A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction/aims: Pacinian corpuscles are end organs of the sensory nervous system. The size and superficial location of Pacinian corpuscles allows them to be visualized with high-resolution ultrasound. This pilot study sought to assess the reliability of Pacinian corpuscle counting in the hand using ultrasound.

Methods: Two healthy participants underwent ultrasound evaluation by three ultrasonographers using a scanning protocol developed for this study. The ultrasound protocol used anatomic landmarks to identify and trace digital nerves in the palms and the adjacent Pacinian corpuscles. The ultrasonographers used morphologic features to identify and count Pacinian corpuscles at two sites in each hand for each participant using a 10-22 MHz linear-array transducer. The procedure was repeated at 2 time points. Inter-rater and intrarater reliabilities were determined using intraclass correlation coefficients (ICCs).

Results: Pacinian corpuscles were identified in the second-third and fourth-fifth intermetacarpal spaces. The ultrasound appearance of Pacinian corpuscles is of a hypoechoic, rounded structure without a hyperechoic rim. A clustered appearance and septate internal structure are distinct features of Pacinian corpuscles, but these features are not always present. The mean number at each site was between 10.71 and 11.71. Inter-rater and intrarater reliability both resulted in ICC values over 0.8, indicating "good" inter-rater and intrarater reliabilities.

Discussion: Pacinian corpuscles can be reliably counted in the hand using high-resolution ultrasound. The reliability data from this pilot study may facilitate further ultrasound studies of Pacinian corpuscles, which may be decreased in number or undergo other changes in polyneuropathies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12138487PMC
http://dx.doi.org/10.1002/mus.28423DOI Listing

Publication Analysis

Top Keywords

pacinian corpuscles
40
pilot study
12
inter-rater intrarater
12
pacinian
11
corpuscles
10
high-resolution ultrasound
8
ultrasound
6
ultrasonographic identification
4
identification pacinian
4
hand
4

Similar Publications