98%
921
2 minutes
20
Extracellular vesicles (EVs) are crucial for intercellular communication and are found in various biological fluids. The identification and immunophenotyping of such small particles continue to pose significant challenges. Here, we have developed a workflow for the optimisation of a next-generation panel for in-depth immunophenotyping of circulating plasma EVs using spectral flow cytometry. Our data collection followed a multistep optimisation phase for both instrument setup and 21-colour panel design, thus maximising fluorescent signal recovery. This spectral approach enabled the identification of novel EV subpopulations. Indeed, besides common EVs released by erythrocytes, platelets, leukocytes and endothelial cells, we observed rare and poorly known EV subsets carrying antigens related to cell activation or exhaustion. Notably, the unsupervised data analysis of major EV subsets revealed subpopulations expressing up to five surface antigens simultaneously. However, the majority of EVs expressed only a single surface antigen, suggesting they may not fully represent the phenotype of their parent cells. This is likely due to the small surface area or the biogenesis of EVs rather than antibody steric hindrance. Finally, we tested our workflow by analysing the plasma EV landscape in a cohort of systemic lupus erythematosus (SLE) patients. Interestingly, we observed a significant increase in CD54 EVs, supporting the notion of elevated circulating ICAM under SLE conditions. To our knowledge, these are the first data highlighting the importance of a spectral flow cytometry approach in deciphering the heterogeneity of plasma EVs paving the way for the routine use of a high-dimensional immunophenotyping in EV research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12025886 | PMC |
http://dx.doi.org/10.1002/jex2.70045 | DOI Listing |
Interv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDFRev Sci Instrum
September 2025
Attosecond Science Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan.
We have developed a vacuum-compatible liquid flat-jet apparatus that delivers stable, sub-micrometer sheets for soft-x-ray spectroscopy. Interchangeable PEEKsil microjets (ϕ 25-100 μm) collide to form a leaf-like jet that runs reproducibly for more than 6 h at ∼0.1 Pa.
View Article and Find Full Text PDFFront Bioeng Biotechnol
August 2025
Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Spectroscopic soft sensors are developed by combining spectral data with chemometric modeling, and offer as Process Analytical Technology (PAT) tools powerful insights into biopharmaceutical processing. In this study, soft sensors based on Raman spectroscopy and linear or partial least squares (PLS) regression were developed and successfully transferred to a filtration-based recovery step of precipitated virus-like particles (VLPs). For near real-time monitoring of product accumulation and precipitant depletion, the dual-stage cross-flow filtration (CFF) set-up was equipped with an on-line loop in the second membrane stage.
View Article and Find Full Text PDFACS Omega
September 2025
Petroleum Exploration and Engineering Lab (LENEP), North Fluminense State University (UENF), Macaé 27930-480, Brazil.
Understanding seismic attenuation in carbonate rocks is critical for improving reservoir characterization and fluid monitoring during hydrocarbon exploration. This study investigated the behavior of P-wave attenuation (1/ ) during fluid substitution from saltwater to oil in coquina samples from the Morro do Chaves Formation, an analogue of Brazilian pre-salt reservoirs. Laboratory experiments were conducted at an ultrasonic frequency (1.
View Article and Find Full Text PDFFront Immunol
September 2025
Institute of Human Virology, University of Maryland School of Medicine, Baltimore, MD, United States.
Innate-like T cells (ILT), including γδ T cells (Vδ2s), Natural Killer T cells (NKTs) and Mucosal-associated Invariant T cells (MAITs), integrate innate and adaptive immunity, playing important roles in homeostatic conditions as well as during infection or inflammation. ILT are present on both sides of the fetal-maternal interface, but our knowledge of their phenotypical and functional features in neonates is limited. Using spectral flow cytometry we characterized cord blood ILT in neonates born to healthy women and women living with HIV.
View Article and Find Full Text PDF