Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Tinostamustine is a first-in-class alkylating deacetylase inhibitor that facilitates access to cancer cell DNA, resulting in its damage and counteracting DNA repair systems. We hypothesize that the addition of tinostamustine to immune checkpoint inhibitors (ICIs) improves melanoma treatment. This open-label, nonrandomized phase IB study characterized dose-limiting toxicity (DLT) and the recommended dose (RD) of 2-weekly intravenous tinostamustine at escalating doses of 15 and 30 mg/m 2 when administered with 2-weekly nivolumab 3 mg/kg added in cycle 2 in patients with melanoma. We included 17 patients (four at 15 mg/m 2 and 13 at 30 mg/m 2 tinostamustine). A total of 13/17 (77%) patients were ICI-resistant, 7/17 (41%) had unfavorable melanoma subtypes. No DLT was identified. Tinostamustine RD was 30 mg/m 2 every 2 weeks. One patient experienced grade 2 nivolumab-associated immune-related pneumonitis. Tinostamustine-associated grade 3 leukocytopenia was documented in one patient, grade 2 leukocytopenia in five patients, and grade 1 thrombocytopenia in three patients. Treatment discontinuation occurred in one patient for nivolumab-associated immune-related pneumonitis and in another patient for tumor-related hemorrhage. A total of 7/13 (54%) evaluable patients had at least stable disease as best treatment response, including 3/13 (23%) patients with a confirmed partial response. Median progression-free survival was 8.3 weeks [95% confidence interval (CI): 2.4-15.4 weeks), median overall survival was 19.1 weeks (95% CI: 2.4-41 weeks). Two-weekly intravenous tinostamustine at an immune-modulatory dose of 30 mg/m 2 is safe when coadministered with nivolumab 3 mg/kg and resulted in 54% disease stabilization and 23% confirmed partial responses in patients with predominantly ICI-resistant, advanced melanoma.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CMR.0000000000001040DOI Listing

Publication Analysis

Top Keywords

patients
9
open-label nonrandomized
8
nonrandomized phase
8
phase study
8
recommended dose
8
advanced melanoma
8
intravenous tinostamustine
8
nivolumab 3 mg/kg
8
patients ici-resistant
8
nivolumab-associated immune-related
8

Similar Publications

Introduction: Wave speed (WS) mapping, enabled by omnipolar technology, allows for real-time visualization of local conduction velocity (CV). Its utility in ventricular tachycardia (VT) ablation has not been fully characterized.

Methods And Results: We describe a case series of patients undergoing VT ablation in which WS mapping was applied alongside established techniques such as peak frequency (PF) mapping and isochronal late activation mapping (ILAM).

View Article and Find Full Text PDF

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Background: Alzheimer's disease (AD) patients and animal models exhibit an altered gut microbiome that is associated with pathological changes in the brain. Intestinal miRNA enters bacteria and regulates bacterial metabolism and proliferation. This study aimed to investigate whether the manipulation of miRNA could alter the gut microbiome and AD pathologies.

View Article and Find Full Text PDF

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

Background: Survivors of critical illness frequently face physical, cognitive and psychological impairments after intensive care. Sensorimotor impairments potentially have a negative impact on participation. However, comprehensive understanding of sensorimotor recovery and participation in survivors of critical illness is limited.

View Article and Find Full Text PDF