Purpose: Wearable technologies, like the Apple Watch, offer new possibilities for collecting objective data on physical activity post-operatively following total knee arthroplasty (TKA). This study aims to describe changes in daily physical activity levels using objective metrics over different time points following TKA.
Methods: This study analyzed data from a prospective cohort of 152 patients undergoing a unilateral TKA. Patients wore an Apple Watch and used a digital care management application for data collection. Step count, steadiness, standing duration, gait speed and performance on a 6-min walk test were collected from Apple HealthKit at multiple time points: pre-operative, 6 weeks post-operatively, 6 months post-operatively and 12 months post-operatively. Statistical analyses were performed using R software, including descriptive statistics and paired t tests to compare outcomes at different time points post-operatively.
Results: Participants demonstrated significant improvements in daily physical activity levels over the course of 12 months post-operative. At 6 months post-operative, participants showed the highest average daily step count (mean ± SD: 5293 ± 236 steps; p < 0.001), with improvements persisting at 12 months post-operative (5180 ± 260 steps; p < 0.001) compared to preoperative values. Gait speed increased from 0.88 ± 0.01 m/s preoperatively to 1.01 ± 0.01 m/s (p = 0.006) at 12 months post-operative. Standing hours increased from 9.99 ± 0.30 to 11.47 ± 0.31 h at 6 months post-operative and persisted. Steadiness and the estimated 6-minute walk test showed recovery trends, though variability remained at 12 months post-operative, suggesting the need for additional longitudinal assessment CONCLUSION: This study provides one of the first longitudinal analyses of post-operative functional recovery using Apple HealthKit, offering continuous real-world gait and activity tracking beyond traditional patient-reported measures. These findings highlight the value of wearable technology in monitoring post-operative activity and offering insights into TKA recovery patterns. The study suggests a critical recovery window at 6 months post-operative and emphasizes the need for ongoing support to maintain improvements. The integration of wearable technology in post-operative monitoring offers a promising approach to tracking patient progress and optimizing functional outcomes following TKA.
Level Of Evidence: Level II.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ksa.12675 | DOI Listing |
Neurorehabil Neural Repair
September 2025
Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, UK.
Background: Gait impairment in Parkinson's disease (PD) occurs early and pharmaceutical interventions do not fully restore this function. Visual cueing has been shown to improve gait and alleviate freezing of gait (FOG) in PD. Technological development of digital laser shoe visual cues now allows for visual cues to be used continuously when walking.
View Article and Find Full Text PDFJ Exp Biol
September 2025
Institute of Environmental Sciences, Faculty of Biology, Jagiellonian University, Kraków, Poland.
The adverse effects of Western diets (WD), high in both fat and simple sugars, which contribute to obesity and related disorders, have been extensively studied in laboratory rodents, but not in non-laboratory animals, which limits the scope of conclusions. Unlike laboratory mice or rats, non-laboratory rodents that reduce body mass for winter do not become obese when fed a high-fat diet. However, it is not known whether these rodents are also resistant to the adverse effects of WD.
View Article and Find Full Text PDFCrit Rev Toxicol
September 2025
Centre for Health Protection, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands.
There is a concern on the safety of cosmetic ingredients and their endocrine-disrupting (ED) potential. Frequent use as well as the use of a diverse range of cosmetics pose a concern for a potential health risk via aggregate exposure to endocrine disrupting chemicals (EDCs). In this study, a list of ingredients available in cosmetic products that were recently introduced to the Dutch market was retrieved from the commercially accessible Mintel database and screened for the presence of EDCs.
View Article and Find Full Text PDFACS Sens
September 2025
State Key Laboratory of Advanced Fiber Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China.
High-fidelity biosignal monitoring is essential for daily health tracking and the diagnosis of chronic diseases. However, developing bioelectrodes capable of withstanding repeated use and mechanical deformation on wet tissue surfaces remains a significant challenge. Here, we present a robust and ultrathin bioelectrode (RUB), featuring a mechanically heterogeneous architecture and a thickness of ∼3 μm.
View Article and Find Full Text PDFEur J Sport Sci
October 2025
University Jean Monnet Saint-Etienne, Lyon 1, University Savoie Mont-Blanc, Inter-university Laboratory of Human Movement Biology, EA 7424, F-42023, Saint-Etienne, France.
The purpose of this study was to evaluate the evolution of jump and sprint force-production capacities with maturation in young soccer players. One hundred sixteen young elite male soccer players aged 11-17 years were assigned to six different groups according to their maturity status. The force-velocity (F-V) profiles in jumping and sprinting performances were compared among groups.
View Article and Find Full Text PDF