A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Chemical, optical, and morphological properties of TPU and PET-G samples after aging in artificial saliva: an in vitro study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Thermoplastic materials, such as glycol-modified polyethylene terephthalate (PET-G) and thermoplastic polyurethane (TPU), undergo alterations due to environmental factors in the oral cavity, which can affect their composition and surface properties over time. While previous studies have explored these changes, a comprehensive characterization of TPU and PET-G properties, particularly after immersion in artificial saliva, remains limited. This study aimed to evaluate the aging process of 24 TPU and 24 PET-G dumbbell-shaped specimens before and after exposure to artificial saliva. The analysis focused on the morphological, chemical, and optical properties of the samples, including thickness, weight, and surface roughness.

Methods: The study examined 48 thermoplastic samples, equally divided between PET-G and TPU. The samples were thermoformed into standardized shapes and analyzed at three time points: after thermoforming (T0), after 7 days (T1), and after 14 days (T2) of immersion in artificial saliva at 37 °C. Measurements included weight, thickness, surface roughness, absorbance, and Fourier transform infrared spectroscopy (FTIR). Data were analyzed using one-way ANOVA to identify significant changes over time, with a significance level of p < 0.01.

Results: Both materials exhibited significant reductions in surface roughness, with TPU showing a decrease in average roughness (Ra) from 99.43 nm at T0 to 76.53 nm at T2 (-23.02%) and PET-G decreasing from 33.25 nm to 20.19 nm (-39.27%). The root mean square roughness (Rq) in TPU declined by 41.67% (from 126.91 nm to 74.02 nm), while PET-G showed a reduction of 28.06% (from 44.98 nm to 32.35 nm). Peak-to-valley roughness (Rt) also decreased by 10.5% in TPU and 27.96% in PET-G. No statistically significant changes were observed in thickness, weight, optical density, or chemical composition (p > 0.01). The roughness disparity between TPU and PET-G persisted even after immersion in saliva.

Conclusions: Following the simulated intraoral aging process, significant changes in surface roughness were observed in TPU and PET-G specimens. The reduction in roughness, particularly a 39.27% decline in PET-G and 23.02% in TPU, has been clinically associated with decreased plaque accumulation and reduced friction between the aligner and the teeth.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11987292PMC
http://dx.doi.org/10.1186/s12903-025-05863-0DOI Listing

Publication Analysis

Top Keywords

tpu pet-g
20
artificial saliva
16
chemical optical
8
tpu
8
pet-g
8
immersion artificial
8
aging process
8
surface roughness
8
optical morphological
4
properties
4

Similar Publications