A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

External validation of a flowchart related to achieving the target area under the concentration-time curve for vancomycin: A retrospective multicenter study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

During therapeutic drug monitoring (TDM) for vancomycin (VCM), the area under the concentration-time curve (AUC) is important for balancing efficacy versus toxicity. In a previous study, we developed a decision tree (DT) model to achieve the target AUC during TDM over the follow-up period (AUC). This study aimed to validate the DT model for achieving the target AUC. Patients who received VCM for at least 72 h and had an initial TDM within four doses between January 2023 and December 2023 were analyzed. The AUC of the initial TDM was calculated over 2-point (peak/trough) concentrations via Bayesian estimation. The target AUC was defined as 400-600 μg h/mL. Among 188 patients (median age [interquartile range], 66 [56, 79] years; 50 % female), the target AUC was achieved in 70 % (132/188). When the predicted AUC was 400-600 μg h/mL, 84 % (102/121) achieved the target AUC. In a 12 h dosing interval subgroup, 86 % (88/102) achieved the target AUC. Conversely, when the predicted AUC was <400 or >600 μg h/mL, the proportion who achieved the target AUC dropped to 44 % (30/67). Only 30 % (3/10) of those with creatinine clearance rates of >130 mL/min/1.73 m achieved the target. The area under the receiver operating characteristics curve was 0.74, and the R value was 0.15. Our findings confirmed the external validity of the DT model and supported its use for optimizing VCM dosing. Overall, the DT model offers a reliable framework for achieving target AUC values during follow-up for TDM, aiding safe and effective treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jiac.2025.102701DOI Listing

Publication Analysis

Top Keywords

target auc
32
achieved target
16
auc
13
achieving target
12
target
10
target area
8
area concentration-time
8
concentration-time curve
8
initial tdm
8
predicted auc
8

Similar Publications