98%
921
2 minutes
20
Introduction: In atrial fibrillation (AF) ablation procedures, the CARTO VIZIGO Bidirectional Guiding Sheath has previously shown promising results in reducing fluoroscopy times without compromising clinical effectiveness or safety compared with non-steerable sheaths.
Methods: This non-randomized, multicenter, retrospective cohort study (INSIGHT) aimed to determine the real-world impact of the VIZIGO sheath on procedural efficiency, clinical effectiveness, and safety in paroxysmal AF (PAF) catheter ablation. Consecutive adults who underwent de novo radiofrequency (RF) ablation for PAF with a non-VIZIGO sheath (January 2019-July 2021) or VIZIGO sheath (January 2020-July 2021) were included. Procedural characteristics, primary adverse events (PAEs), and 12-month effectiveness (freedom from repeat ablation or recurrent atrial arrhythmia) were evaluated.
Results: Of 199 patients included (mean age, 69.7 years; 59.3% male), 97 had ablation with a VIZIGO sheath and 102 with a non-VIZIGO sheath. Significantly shorter mean times were achieved in the VIZIGO vs. non-VIZIGO group for time to left PVI (18.1 ± 7.5 vs. 19.9 ± 5.6 min, p = 0.046), right PVI (16.5 ± 6.1 vs. 23.1 ± 9.9 min, p < 0.001), total PVI (34.6 ± 9.7 vs. 42.9 ± 11.4 min, p = 0.002), and fluoroscopy time (7.3 ± 10.4 vs. 18.3 ± 13.3 min, p < 0.001). Mean fluoroscopy dose was significantly lower (45.9 ± 112.0 vs. 139.5 ± 251.5 mGy, p < 0.001) with VIZIGO vs. non-VIZIGO sheaths. Catheter stability was comparable between groups. PAE rates were similar in the VIZIGO (3.1%) and non-VIZIGO (4.9%) groups. Freedom from repeat ablation and recurrent atrial arrhythmia at 12 months were also similar in the two groups.
Conclusion: These real-world data demonstrate that use of the VIZIGO sheath in PAF ablation procedures allows for significantly lower fluoroscopy time and dose with significantly shorter PVI isolation time, without compromising acute and long-term effectiveness or safety.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12160683 | PMC |
http://dx.doi.org/10.1111/jce.16658 | DOI Listing |
J Cardiovasc Electrophysiol
June 2025
Kobe City Medical Center General Hospital, Kobe, Japan.
Introduction: In atrial fibrillation (AF) ablation procedures, the CARTO VIZIGO Bidirectional Guiding Sheath has previously shown promising results in reducing fluoroscopy times without compromising clinical effectiveness or safety compared with non-steerable sheaths.
Methods: This non-randomized, multicenter, retrospective cohort study (INSIGHT) aimed to determine the real-world impact of the VIZIGO sheath on procedural efficiency, clinical effectiveness, and safety in paroxysmal AF (PAF) catheter ablation. Consecutive adults who underwent de novo radiofrequency (RF) ablation for PAF with a non-VIZIGO sheath (January 2019-July 2021) or VIZIGO sheath (January 2020-July 2021) were included.
Front Cardiovasc Med
January 2025
Department of Cardiology, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
Background: Dextrocardia is a rare congenital condition, affecting approximately 1 in 10,000-12,000 individuals. When combined with atrial fibrillation (AF), it becomes even rarer. "One-stop" surgery, including combined radiofrequency ablation (RFA) and left atrial appendage occlusion (LAAO), has become a common clinical treatment for patients with AF who develop cerebral infarction despite regular oral anticoagulants.
View Article and Find Full Text PDFPacing Clin Electrophysiol
March 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFJ Cardiothorac Surg
June 2024
Department of Cardiology, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, Jiangxi, 330006, P. R. China.
J Thorac Dis
March 2024
Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Background: A novel visualized steerable sheath, referred to as the Vizigo sheath, has been utilized in clinical interventions. The objective of this study was to evaluate and contrast the efficacy and safety of the Vizigo sheath with other sheaths in the catheter ablation (CA) for focal atrial tachycardia (FAT).
Methods: A retrospective cohort study was conducted on consecutive patients with CA for FAT from March 2019 to February 2022.