A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A pyrene based novel di-Schiff base colorimetric and turn-on fluorescent-chemosensor for selective and sensitive detection of Hg ion: Biological, logic gate and real sample applications. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Following a simple synthetic process, a new pyrene derivative with a benzildihydrazone moiety has been synthesised and used for selective detection of Hg across four distinct channels (colorimetric, absorption, emission, and bio-imaging). When Hg was present, the chemosensor L exhibited a noticeable increase in fluorescence, changing colour from yellow to colourless, while other metal ions only caused slight variations in fluorescence intensity as well as colour. The fluorescent-based assay's sensitivity for Hg is 1.04 × 10 M and colorimetric detection limit is 7.83 × 10 M, which are significantly lower than the threshold specified in the World Health Organization's (WHO) drinking water guidelines. The 1:1 stoichiometric complexation between L and Hg is demonstrated by the Job plot, and the ESI-MS spectra data. L has practical applications in real sample analysis, molecular logic gate and biology. Confocal fluorescence microscopy imaging in MCF 7 and human lymphocyte cells (HLCs) showed that L could be used as an effective fluorescent probe for detecting Hg in living cells. Moreover L may be employed as anticancer drug without causing any harmful consequences at the given concentrations and incubation duration. L has also real sample and logic gate application.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2025.126104DOI Listing

Publication Analysis

Top Keywords

logic gate
12
real sample
12
pyrene based
4
based novel
4
novel di-schiff
4
di-schiff base
4
base colorimetric
4
colorimetric turn-on
4
turn-on fluorescent-chemosensor
4
fluorescent-chemosensor selective
4

Similar Publications