A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Repeatability of fully automated, inline quantitative assessment of myocardial perfusion in patients with suspected coronary artery disease. | LitMetric

Repeatability of fully automated, inline quantitative assessment of myocardial perfusion in patients with suspected coronary artery disease.

Eur Heart J Imaging Methods Pract

Department of Cardiovascular Sciences, University of Leicester, and the National Institute for Health and Care Research (NIHR) Leicester Cardiovascular Biomedical Research Centre, Glenfield Hospital, Leicester LE3 9QP, UK.

Published: October 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: Recent developments in the field of myocardial perfusion assessment with cardiovascular magnetic resonance (CMR) enable the automated inline quantification of myocardial blood flow (MBF). Previous studies have assessed its repeatability in healthy volunteers. This study assessed the repeatability of this technique in patients with suspected stable coronary artery disease (CAD).

Methods And Results: Patients with suspected CAD were studied twice on separate days. CMR perfusion imaging was performed at rest and during adenosine stress using a dual-sequence T1-weighted saturation recovery gradient echo sequence. Inline automatic reconstruction and image post-processing were implemented within the Gadgetron software framework, calculating MBF using a blood tissue exchange model. Repeatability of global stress and rest MBF, and myocardial perfusion reserve (MPR) were evaluated using Bland-Altman plots and intraclass correlation coefficients. Fifty-four patients (mean age 67 ± 9 years, 78% male) were studied. The median interval between the two scans was 2 days (IQR 3). There was no significant interstudy difference in global stress MBF (1.46 ± 0.51 mL/min/g vs. 1.51 ± 0.59mLmin/g, = 0.44), global rest MBF (0.54 ± 0.14 mL/min/g vs. 0.56 ± 0.16 mL/min/g, = 0.48), or global MPR (2.72 ± 0.80 vs. 2.84 ± 1.13, = 0.76) between the two scans. Stress MBF, rest MBF, and MPR showed intraclass correlations of 0.60 (95% CI 0.39-0.75), 0.63 (95% CI 0.36-0.77), and 0.39 (95% CI 0.09-0.62), respectively.

Conclusion: In patients with suspected CAD, quantitative assessment of myocardial perfusion by fully automated inline myocardial mapping shows moderate repeatability for stress and rest MBF, but poorer repeatability with MPR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11935528PMC
http://dx.doi.org/10.1093/ehjimp/qyaf026DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
16
patients suspected
16
rest mbf
16
automated inline
12
fully automated
8
quantitative assessment
8
assessment myocardial
8
coronary artery
8
artery disease
8
mbf
8

Similar Publications