A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Micro-Electrometric Method for Assessing Cholinesterase Activity in Human Whole Blood. | LitMetric

Micro-Electrometric Method for Assessing Cholinesterase Activity in Human Whole Blood.

Methods Protoc

School of Health Science Research, Research Institute for Health Sciences, Chiang Mai University, Chiang Mai 50200, Thailand.

Published: March 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cholinesterase (ChE) is an essential enzyme for nervous system function, and its activity in the blood serves as a biomarker for pesticide exposure, necessitating accessible assessment methods in resource-limited areas. This study focused on developing and validating a micro-electrometric method to rapidly and reliably measure ChE activity in human blood to monitor pesticide exposure. A micro-electrometric method was designed to evaluate ChE activity in whole-blood samples, involving incubation with organophosphate and carbamate pesticides and subsequent pH measurement, and its performance was compared to that of the Ellman method. The optimized method was strongly correlated with the Ellman method (R = 0.9147), effectively measuring dose-dependent ChE inhibition by mevinphos and carbofuran with stabilization after 10 min, demonstrating a high sensitivity suitable for field applications. The micro-electrometric method is easy, accurate, and inexpensive for measuring ChE activity. It has been proven to work by comparing it to other methods; therefore, it can be used in clinical and research settings with limited resources.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11932293PMC
http://dx.doi.org/10.3390/mps8020030DOI Listing

Publication Analysis

Top Keywords

micro-electrometric method
16
che activity
12
activity human
8
human blood
8
pesticide exposure
8
ellman method
8
method
6
activity
5
che
5
micro-electrometric
4

Similar Publications