Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Endoscopic endonasal surgery (EES) has become increasingly popular, yet anatomical constraints posed by the nose and limitations of nonarticulated instruments render EES technically challenging, with a steep associated learning curve. Therefore, we developed a handheld robot to enhance dexterity in endoscopic neurosurgical procedures. A previous trial of the robot demonstrated its potential advantages in endoscopic neurosurgery but also the need for improvements. In this study, we assess the feasibility, acceptability, and comparative performance of the updated robotic prototype (version 0.2) against standard instruments in a preclinical phantom and cadaveric trial. Ethical approval was received. Participants were stratified according to their neurosurgical experience. In the phantom study, a randomized crossover design compared the robot against standard instruments at a phantom tumor resection task. Statistical analysis was performed using Mann-Whitney U tests and paired -tests. In the cadaver-based user study, participants evaluated the device's functional domains through a qualitative interview design. In the phantom study, the device demonstrated a learning curve: initial resection attempts favored the traditional instrument (84% vs. 59%, = 0.055), but parity was achieved by the fifth attempt (80% vs. 83%, = 0.76). Acceptability was evident, as most clinicians (7/8) preferred the robot for its superior range, ergonomics, and precision. Also, the robot exhibited a diminished cognitive workload. The cadaveric study underscored the robot's clinical feasibility, through sufficient workspace reach and force delivery. : Overall, our robot demonstrates promising acceptability and feasibility for endoscopic neurosurgery, yet further iterative developments are required before proceeding to in-human clinical trials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11913540 | PMC |
http://dx.doi.org/10.1055/a-2297-3647 | DOI Listing |