Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The prognostic value of defibrillators in cardiac resynchronization therapy (CRT) for primary prevention remains debatable. Predicting ventricular arrhythmias (VAs) before implantation is useful for deciding whether to add a defibrillator to a CRT device. This study aimed to determine the risk factors for VA events after CRT device implantation and to construct a scoring model. A total of 153 patients who underwent CRT device implantation, with no history of sustained ventricular tachycardia or ventricular fibrillation (including 25 patients with CRT pacemakers) and with follow-up period >1 year after implantation were included. We assessed VA events requiring implantable cardioverter-defibrillator therapy and sustained VA events requiring clinical treatment. During a mean follow-up of 6.3 years, 24 patients (16%) received therapy for VA. Multivariate analysis revealed age ≤ 70 years (hazard ratio [HR] 2.936, P = 0.037), administration of tolvaptan (HR 11.259, P < 0.001), and coronary artery disease (HR 2.444, P = 0.045) were independent predictors for VA events. Risk scores were assigned based on the HR for each predictor, and the population was divided into 3 risk groups (low: 0 points; moderate: 1-3 points; high: 4-5 points). VAs occurred less frequently in the low-risk group than in the other risk groups (low: 8.1%; moderate: 18%; high: 21%) (log-rank, P < 0.001). No significant differences in mortality were observed between the groups, whereas hospitalization for heart failure occurred more frequently in the high-risk group than in the other groups. In conclusion, a scoring system using specific background information may help predict VA events in prophylactic CRT recipients.

Download full-text PDF

Source
http://dx.doi.org/10.1536/ihj.24-646DOI Listing

Publication Analysis

Top Keywords

crt device
12
scoring system
8
cardiac resynchronization
8
resynchronization therapy
8
primary prevention
8
device implantation
8
events requiring
8
risk groups
8
groups low
8
occurred frequently
8

Similar Publications

Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, but prior interventions like percutaneous mitral annuloplasty may hinder lead placement. We present a 70-year-old male with ischemic cardiomyopathy and severe functional mitral regurgitation who previously received a Carillon device. Due to coronary sinus inaccessibility, left bundle branch area pacing optimized cardiac resynchronization therapy (LOT-CRT) was performed.

View Article and Find Full Text PDF

Acute extremity compartment syndrome (CS) is a serious medical complication triggered by factors such as trauma, vascular injury, or prolonged compression, resulting in elevated intracompartmental pressure (ICP) and tissue ischemia. Diagnosis remains challenging, mainly relying on the subjective evaluation of clinical symptoms. Different animal models have been used to study pathophysiology and evaluate diagnostic and therapeutic approaches.

View Article and Find Full Text PDF

Complications after complex device implantation: how important is implanter seniority?

Open Heart

September 2025

King's British Heart Foundation Centre of Research Excellence, School of Cardiovascular and Metabolic Medicine & Sciences, King's College London, London, UK.

Background: The complication risk of procedures may be influenced by operator and institutional characteristics. Our aim was to assess whether supervising consultant seniority and operative volume, and hospital volume were associated with the risk of reintervention following complex device implantation.

Methods: A nationwide population-based study was performed using the National Institute for Cardiovascular Outcomes Research registry including all patients receiving their first transvenous implantable cardioverter defibrillator or cardiac resynchronisation therapy (CRT) implant in England over 5 years (April 2014-March 2019).

View Article and Find Full Text PDF

Background: Cardiac resynchronization therapy (CRT) has been established as a key component in the management of patients with heart failure (HF) with reduced ejection fraction in addition to pharmacologic therapy. Several automatic algorithms have been developed to optimize the timing cycle settings in CRT, especially AV delay which was associated with improvement of the response to CRT. The present study aims to investigate whether the novel device-based SyncAV algorithm could elicit better synchrony and acute hemodynamic response.

View Article and Find Full Text PDF

Heart failure readmissions remain a major challenge for healthcare systems, contributing significantly to morbidity, mortality, and increased healthcare costs. Despite advancements in medical and device-based therapies, rehospitalization rates remain high, particularly within the first 30 days of discharge. This review aims to evaluate the primary factors associated with HF readmissions and discuss evidence-based strategies to reduce these rates.

View Article and Find Full Text PDF