Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application. This paper proposes a new PET device, Scratch-PET, for image-guided tumor resection. The key feature of Scratch-PET is its use of a hand-held detector to scan the surgical field, ensuring open space for surgery while measuring annihilation radiation with a fixed detector array placed below the patient. We developed a prototype device using two detectors: the hand-held detector and a fixed detector, to demonstrate the feasibility of the proposed concept. Both detectors consisted of 16 × 16 arrays of lutetium yttrium orthosilicates (3 × 3 × 15 mm) coupled one-to-one with 16 × 16 silicon photomultiplier arrays. The position and orientation of the hand-held detector are tracked using an optical tracking sensor that detects attached markers. We measured a Na multi-rod phantom and two Na point sources separately for 180 s while moving the hand-held detector. The rod diameters were 6.0, 5.0, 4.0, 3.0, 2.2, and 1.6 mm. Each point source was placed at the field-of-view center and 35 mm off-center which was outside the sensitive area when the hand-held detector was positioned facing the fixed detector. The 2.2 mm rods were partially resolved, and both point sources were successfully visualized. The potential of the proposed device to visualize small tumors was validated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12103487PMC
http://dx.doi.org/10.1007/s12194-025-00889-zDOI Listing

Publication Analysis

Top Keywords

hand-held detector
24
fixed detector
12
detector
10
intraoperative pet
8
point sources
8
hand-held
6
initial demonstration
4
demonstration scratch-pet
4
scratch-pet concept
4
concept intraoperative
4

Similar Publications

Rapid and Selective Detection of Trace Hydrogen by Mesoporous SnO Anchored with Au-Pd Dual-Atom Sensitizers.

Nano Lett

May 2025

The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.

Due to weak interactions between hydrogen molecules and sensing materials as well as slow H oxidation kinetics, traditional semiconductor metal oxides (SMOs) have limited capability for selective and rapid hydrogen sensing. We propose an innovative strategy to enhance gas-sensing performance by modifying SMOs with atomically dispersed dual noble-metal sensitizers, differing from conventional single-atom or nanoparticle sensitizers. This sensor shows fast response time (1 s), strong resistance to CO, NO, HS, and SO interference, and an ultralow detection limit (70 ppb) toward hydrogen, surpassing single noble-metal modified hydrogen sensors.

View Article and Find Full Text PDF

Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application.

View Article and Find Full Text PDF

Thin-film fluorescent chemosensors, characterized by their tunable design, high selectivity, and exceptional sensitivity, hold significant promise for gas detection applications. However, the simultaneous realization of the 3S attributes (sensitivity, selectivity, and stability) remains a formidable challenge, particularly in the underexplored field of near-infrared (NIR) gas detection. In this work, we employ an acceptor-donor-acceptor (A-D-A) molecular design strategy to drive the development of an organic semiconductor fluorescent material with a progressive red shift in the emission wavelength.

View Article and Find Full Text PDF

To establish a radiological national reference for agricultural soil across Tunisian oases and assess the risk to human health associated with date consumption, with a focus on comparing the impact of traditional and modern fertilization, radiological parameters and activity levels of ⁶Ra, Th, and ⁰K were determined for 27 oases. These oases were located in three southern Tunisian governorates. The activity concentration of ⁶Ra, Th, and ⁰K was measured using a 3 × 3 inch NaI(Tl) scintillation detector, which was found to be 21.

View Article and Find Full Text PDF

Visible diffuse reflectance smartphone spectrometer with high spectral accuracy.

Spectrochim Acta A Mol Biomol Spectrosc

February 2025

Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh. Electronic address:

Article Synopsis
  • A smartphone-based spectrometer is designed for analyzing solid samples using diffuse reflection, featuring a thin-film grating and a diffuse surface to capture light.
  • The device simplifies optical setup by directly using a smartphone's CMOS camera to capture light without needing complex optics, achieving a maximum wavelength resolution of 0.08 nm/pixel within a spectrum of 400-700 nm.
  • It successfully identifies food color pigments and detects possible food adulteration, offering a compact, affordable (around $50), and portable solution for on-site testing.
View Article and Find Full Text PDF