A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Verification of the accuracy and design time of crowns designed with artificial intelligence. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study examines the potential of computer-aided design (CAD) systems equipped with artificial intelligence (AI) in reducing the workload of dental technicians. We aimed to compare the accuracy and design time of crowns designed using conventional CAD with those designed using AI-equipped CAD.

Materials And Methods: Abutment tooth models of a maxillary right second premolar (FDI classification #15) and a maxillary left first molar (FDI classification #26) were mounted on a dental model to form the master model. Stereolithography data were acquired using an intraoral scanner, and five dental technicians designed one crown each for #15 and #26 using both conventional and AI-equipped CAD systems. With the #15 and #26 crowns, six measuring points were established for comparing the accuracy of the occlusal surfaces and design time of the crowns designed by the two CAD systems. The occlusal surfaces were also compared for the buccal and palatal sides.

Results: The accuracy of the occlusal surface was 275.5 ± 116.8 µm and 25.7 ± 13 µm for the conventional CAD and AI-equipped CAD systems, respectively. For the buccal and palatal surface comparisons, the conventional CAD system revealed larger misfits on the palatal side for both #15 and #26, with significant differences observed. No significant differences were noted with the AI-equipped CAD system. The AI-equipped CAD resulted in significantly faster design time for both #15 and #26.

Conclusion: The AI-based CAD system significantly reduced design time and enabled the fabrication of uniform crowns regardless of the dental technician's experience and skill.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11886404PMC
http://dx.doi.org/10.4047/jap.2025.17.1.1DOI Listing

Publication Analysis

Top Keywords

design time
20
cad systems
16
ai-equipped cad
16
time crowns
12
crowns designed
12
conventional cad
12
#15 #26
12
cad system
12
cad
10
accuracy design
8

Similar Publications