Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background & Aims: Accurate HDV RNA quantification is crucial for diagnosis and management of chronic hepatitis delta (CHD), yet a significant variability between assays exists. We compared three methods to quantify HDV RNA levels in untreated and bulevirtide (BLV)-treated patients with CHD.
Methods: Frozen plasma from untreated and BLV-treated patients with CHD were tested in a single-center retrospective study using three different assays: Robogene 2.0 HDV RNA Quantification Kit 2.0 (Roboscreen GmbH; limit of detection [LOD] 6 IU/ml on 7500 Fast Real-Time PCR System [Applied Biosystem]), EurobioPlex HDV PCR quantitative kit (Eurobio Scientific; LOD 100 IU/m) on CFX96™ real-time PCR detection system [Bio-Rad]), and AltoStar HDV RT-PCR RUO Kit 1.5 (Altona Diagnostics; estimated LOD <10 IU/ml) on the AltoStar®AM16.
Results: Overall, 431 plasma samples from 130 patients with CHD (69 untreated and 61 BLV-treated) were studied. Compared with Robogene 2.0, EurobioPlex reported higher HDV RNA levels (3.78 [0.70-7.99] . 4.69 [2.00-8.19] log IU/ml, <0.0001), with viremia higher than >0.5 log in 160 (69%). Likewise, HDV RNA levels were higher with AltoStar than with Robogene 2.0 (3.32 [0.70-7.37] . 3.91 [0.19-7.54] log IU/ml, <0.0001), with AltoStar reporting HDV RNA levels >0.5 log in 127 (52%). Although virological response rates (≥2 log decline baseline) at Weeks 24 (Robogene 2.0 EurobioPlex and AltoStar) and 48 (Robogene 2.0 AltoStar) were similar across assays, rates of HDV RNA undetectability significantly differed between the three assays at Weeks 24 and 72 ( = 0.003 and = 0.02, respectively).
Conclusions: HDV RNA levels quantified by EurobioPlex and AltoStar were 1 and 0.5 logs higher than those quantified by Robogene 2.0, respectively. HDV RNA undetectability rates during BLV treatment were assay-dependent.
Impact And Implications: Management and diagnosis of chronic hepatitis delta (CHD) require standardized tests for HDV RNA quantification. Quantification of HDV RNA is significantly influenced by the quantification method, with EurobioPlex detecting approximatively 1 log and AltoStar 0.5 log IU/ml more than Robogene 2.0, respectively. The HDV RNA undetectability rates during BLV monotherapy significantly differed among assays. These findings are of clinical relevance as patients who achieve negative viremia during BLV monotherapy might be entitled to stop therapy successfully.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11883403 | PMC |
http://dx.doi.org/10.1016/j.jhepr.2024.101299 | DOI Listing |