A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

SSN: Monitoring liver injure through signal separation network in dynamic fluorescence molecular tomography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dynamic fluorescence molecular tomography (DFMT) is a promising molecular imaging technique that offers the potential to monitor fast kinetic behaviors within small animals in three dimensions. Early monitoring of liver disease requires the ability to distinguish and analyze normal and injured liver tissues. However, the inherent ill-posed nature of the problem and energy signal interference between the normal and injured liver regions limit the practical application of liver injury monitoring. In this paper, a novel Signal Separation Net (SSN) is proposed to distinguish normal and injured liver tissue for early liver injury monitoring and liver injury localization. By employing a Convolutional Long Short-Term Memory (ConvLSTM) model, SSN first separates the projections of liver injury from the surface photon distribution of DFMT. Then, a ResNet is employed to establish the nonlinear relationship between the liver injury projections and liver injury localization. Experimental findings underscore the viability of the proposed SSN in achieving promising performance in liver injury monitoring using DFMT, demonstrating significant potential for advancing early liver disease monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC53108.2024.10782519DOI Listing

Publication Analysis

Top Keywords

liver injury
28
liver
13
monitoring liver
12
normal injured
12
injured liver
12
injury monitoring
12
signal separation
8
dynamic fluorescence
8
fluorescence molecular
8
molecular tomography
8

Similar Publications