A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Wearable cardioverter defibrillator after ICD-system explantation: data from a multicenter registry. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Data on the use of the wearable cardioverter defibrillator (WCD) among patients after cardiac implantable electronic device explantation of 1- to 3-chamber implantable cardioverter defibrillator systems (ICD) are sparse. Accordingly, several guidelines give a different recommendation regarding WCD indication in this cohort. We aimed to study the baseline characteristics and outcome of patients treated with WCD after ICD explantation. The primary outcome is appropriate WCD shock. Within a multicenter registry 109 patients received a WCD to bridge the time after ICD-system explantation until reimplantation due to a persistent ICD-indication. The mean follow-up was 824 ± 773 days. In addition to ventricular tachyarrhythmias and/or WCD shocks during WCD wear time, also the rate of rehospitalization for ventricular tachyarrhythmias, atrial fibrillation, stroke and congestive heart failure after ICD-reimplantation was evaluated. Patients had a mean age of 65 ± 14 years, and were hospitalized for 21 ± 15 days. The index left ventricular ejection fraction (LVEF) was at baseline 35.7 ± 14.1% and 35.7 ± 14.2% at short-term follow-up. Mean wear time of the WCD was 61 ± 46 days after ICD-system explantation. During that time an appropriate WCD shock was documented in 7.3% of patients. Up to 80.6% of patients after ICD-system explantation were re-implanted. The rates of rehospitalization due to ventricular tachyarrhythmias, heart failure and atrial fibrillation were 7.3%, 6.8% and 4.1%, respectively. After ICD-reimplantation the rate of appropriate shocks was 12/89 (13.4%). Occurrence of malignant ventricular tachyarrythmia after ICD-system explantation is high and the use of WCD among these patients could be beneficial in preventing sudden cardiac death.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11873030PMC
http://dx.doi.org/10.1038/s41598-025-91046-4DOI Listing

Publication Analysis

Top Keywords

icd-system explantation
20
cardioverter defibrillator
12
ventricular tachyarrhythmias
12
wcd
10
wearable cardioverter
8
multicenter registry
8
wcd patients
8
appropriate wcd
8
wcd shock
8
wear time
8

Similar Publications