A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Profiling of Biofluid Metabolites with a Kinetically Differentiated Binary Biosensing Platform. | LitMetric

Profiling of Biofluid Metabolites with a Kinetically Differentiated Binary Biosensing Platform.

Anal Chem

The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou 215123, China.

Published: March 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Biofluid metabolites have a crucial linkage with the health of the human body, and developing a universal method for metabolite monitoring is imperative for disease diagnosis and health management. Herein, we report a kinetically differentiated binary biosensing platform that is specifically responsive to NAD(P)H for profiling diverse biofluid metabolites. The kinetically differentiated binary biosensing platform comprises a cyanine derivative dye with fast reaction kinetics and a quinolinium derivative dye with slow reaction kinetics. Compared to the traditional unitary strategy for NAD(P)H detection, the linear range of the binary biosensing platform is widened by up to 20 times. NAD(P)H are ubiquitous cofactors in living systems, and metabolite production generally involves the consumption or generation of NAD(P)H. Thus, biofluid metabolites can be easily quantified by measuring the variation of NAD(P)H concentration during biochemical reactions with the binary biosensing platform. In this study, serum sorbitol, 2-hydroxybutyric acid (2HB), and α-ketoglutarate (AKG) were all quantified by the binary biosensing platform with accuracies higher than 93%. The kinetically differentiated binary biosensing platform can be extended to the analysis of any molecule that can react directly or indirectly with NAD(P)H. In addition, we constructed a paper-based assay with the binary biosensing platform, and the test papers showed good promise in the point-of-care (POC) profiling of biofluid metabolites. This study proposes a simple strategy to expand the calibration range of traditional unitary detection systems and further provides a universal paradigm for high throughput profiling of disease-associated biomolecules, which offers good promise in disease diagnosis and health management.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.4c03404DOI Listing

Publication Analysis

Top Keywords

binary biosensing
32
biosensing platform
32
biofluid metabolites
20
kinetically differentiated
16
differentiated binary
16
profiling biofluid
8
metabolites kinetically
8
binary
8
biosensing
8
platform
8

Similar Publications