A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Designing Positionally Stable Smooth Breast Implants. | LitMetric

Designing Positionally Stable Smooth Breast Implants.

ACS Biomater Sci Eng

Laboratory of Bioregenerative Medicine and Surgery, Division of Plastic Surgery, Weill Cornell Medicine, New York, New York 10065, United States.

Published: March 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

: The voluntary recall and ban of several textured breast implant models worldwide, secondary to their association with Breast Implant-Associated Anaplastic Large Cell Lymphoma, has limited the key benefit of a textured surface─positional stability. We have engineered a Positionally Stable Smooth Implant (PSSI) containing millimeter-scaled cylindrical wells on the implant surface for capsule ingrowth and device stabilization. : To evaluate the long-term positional stability of PSSI designs and characterize capsule formation. : Miniature breast implants were manufactured using poly(dimethylsiloxane). PSSI were designed with various dimensions of well width, depth, and number. Comparison groups consisted of smooth and textured implants. Six sterilized implants per group were implanted subcutaneously into the bilateral dorsa of Sprague-Dawley rats. Implant rotation was measured with MicroCT every 2 weeks. Implant-capsule units were explanted at 3 months for histological analysis. : All PSSI groups exhibited significantly less cumulative positional rotation than smooth implants ( < 0.05), with stability comparable to that of textured implants. Upon explantation, microCT and gross examination revealed notable capsule ingrowth within the PSSI wells. Histological evaluation of foreign body response showed significantly fewer pro-inflammatory M1 macrophages in the PSSI capsules compared to the textured control. Additionally, myofibroblast expression, which is implicated in capsular contracture, was significantly lower in both the PSSI and textured groups compared to smooth implants. : This novel smooth-surface breast implant design provided equivalent positional stability and reduced pro-inflammatory M1 macrophage expression compared to textured implants. These results suggest a promising, safer alternative to textured implants for inducing positional stability.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsbiomaterials.4c02222DOI Listing

Publication Analysis

Top Keywords

textured implants
16
positional stability
12
implants
9
positionally stable
8
stable smooth
8
breast implants
8
textured
8
breast implant
8
capsule ingrowth
8
smooth implants
8

Similar Publications