A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessing Sensitivity of Brain-to-Scalp Blood Flows in Laser Speckle Imaging by Occluding the Superficial Temporal Artery. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cerebral blood flow is a critical metric for cerebrovascular monitoring, with applications in stroke detection, brain injury evaluation, aging, and neurological disorders. Non-invasively measuring cerebral blood dynamics is challenging due to the scalp and skull, which obstruct direct brain access and contain their own blood dynamics that must be isolated. We developed an aggregated seven-channel speckle contrast optical spectroscopy system to measure blood flow and blood volume non-invasively. Each channel, with distinct source-to-detector distance, targeted different depths to detect scalp and brain blood dynamics separately. By briefly occluding the superficial temporal artery, which supplies blood only to the scalp, we isolated surface blood dynamics from brain signals. Results on 20 subjects show that scalp-sensitive channels experienced significant reductions in blood dynamics during occlusion, while brain-sensitive channels experienced minimal changes. This provides experimental evidence of brain-to-scalp sensitivity in optical measurements, highlighting optimal configuration for preferentially probing brain signals non-invasively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11838768PMC

Publication Analysis

Top Keywords

blood dynamics
20
blood
10
occluding superficial
8
superficial temporal
8
temporal artery
8
cerebral blood
8
blood flow
8
brain signals
8
channels experienced
8
brain
5

Similar Publications