A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Automated Injectors versus Manual Administration: A Comparative Analysis of Radiation Exposure Reduction in F-FDG Delivery. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

 Despite the presence of safety protocols, the manual manipulation of radiopharmaceuticals continues to pose a significant occupational radiation risk. Health care professionals in nuclear medicine are at risk of radiation exposure, particularly to their hands and eyes. Despite existing protective measures, manual handling of radiopharmaceuticals remains a significant source of occupational radiation.  This study evaluates the effectiveness of automated injectors in reducing radiation exposure among health care workers during fluorine-18 fluorodeoxyglucose ( F-FDG) administrations, compared with traditional manual injection methods.  We assessed radiation exposure levels associated with manual versus automated F-FDG injection techniques using specialized dosimeters. Measurements focused on whole-body, extremity, and eye-lens radiation doses to evaluate the potential benefits of automation in minimizing exposure.  Findings reveal that automated injectors significantly reduce radiation exposure, with decreases of 97.97 and 98.96% in left- and right-hand extremity doses, respectively, 43.24% in eye-lens dose, and 91.66% in whole-body dose compared with manual methods.  Automated injection systems offer considerable advantages in reducing health care worker radiation exposure in nuclear medicine. The substantial reduction in staff doses underscores the necessity of transitioning to such technology to promote safer clinical environments. This study highlights the critical role of automation in enhancing occupational safety standards within diagnostic radiology settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11828645PMC
http://dx.doi.org/10.1055/s-0044-1791781DOI Listing

Publication Analysis

Top Keywords

radiation exposure
24
automated injectors
12
health care
12
radiation
9
occupational radiation
8
nuclear medicine
8
exposure
7
manual
6
automated
4
injectors versus
4

Similar Publications